SpecNo.JELF243A-0111B-01 P.3/11
MURATA MFG.CO., LTD
Reference Only
5.
Appearance and Dimensions
■Unit mass (Typical value)
0.003g
(in mm)
6. Electrical Performance
No. Item Specification Test Method
6.1
Inductance
Inductance shall meet item 3.
Measuring Equipment:KEYSIGHT E4982A or equivalent
Measuring Frequency:
<Inductance> 250MHz /
1.6nH~
43nH
200MHz /
47nH~
68nH
150MHz /
72nH~150nH
100MHz / 180nH~390nH
<Q>
250MHz /
1.6nH~
43nH
200MHz /
47nH~
68nH
150MHz /
72nH~150nH
100MHz / 180nH~390nH
Measuring Condition:Test signal level / about 0dBm
Electrode spaces / 1.0 mm
Electrical length / 1.00mm
Measuring Fixture:KEYSIGHT 16197A
Position coil under test as shown in below and contact coil
with each terminal by adding weight.
Measuring Method:See the endnote.
<Electrical Performance:Measuring
Method of Inductance/Q>
6.2
Q Q shall meet item 3.
6.3 DC Resistance DC Resistance shall meet item 3.
Measuring Equipment:Digital multi meter
6.4 Self Resonant
Frequency
(S.R.F)
S.R.F shall meet item 3.
Measuring Equipment:KEYSIGHT N5230A or equivalent
1.6±0.2
0.3±0.1
0.8±0.2
0.4 max.
0.2±0.1
0.3±0.1
0.8±0.15
0.8±0.2
0.8±0.3
1608 size guide