Obsolete Product(s) - Obsolete Product(s)
DC and AC parameters M27V322
14/23
Table 7. Read mode DC characteristics
(1)
(2)
1. T
A
= –40 to 85 °C or 0 to 70 °C; V
CC
= 3.3V ± 10%; V
PP
= V
CC
2. V
CC
must be applied simultaneously with or before V
PP
and removed simultaneously or after V
PP
.
Symbol Parameter Test Condition Min Max Unit
I
LI
Input Leakage Current 0V ≤ V
IN
≤
V
CC
±1 µA
I
LO
Output Leakage Current 0V ≤ V
OUT
≤
V
CC
±10 µA
I
CC
Supply Current
E
= V
IL
, GV
PP
= V
IL
,
I
OUT
= 0mA, f = 5MHz
30 mA
I
CC1
Supply Current (Standby)
TTL
E
= V
IH
1mA
I
CC2
Supply Current (Standby)
CMOS
E
> V
CC
– 0.2V 60 µA
I
PP
Program Current V
PP
= V
CC
10 µA
V
IL
Input Low Voltage –0.6 0.2V
CC
V
V
IH
(3)
3. Maximum DC voltage on Output is V
CC
+0.5V.
Input High Voltage 0.7V
CC
V
CC
+ 0.5 V
V
OL
Output Low Voltage I
OL
= 2.1mA 0.4 V
V
OH
Output High Voltage TTL I
OH
= –400µA 2.4 V
Table 8. Programming mode DC characteristics
(1)
(2)
1. T
A
= 25 °C; V
CC
= 6.25V ± 0.25V; V
PP
= 12V ± 0.25V
2. V
CC
must be applied simultaneously with or before V
PP
and removed simultaneously or after V
PP
.
Symbol Parameter Test Condition Min Max Unit
I
LI
Input Leakage Current V
IL
≤ V
IN
≤ V
IH
±10 µA
I
CC
Supply Current 50 mA
I
PP
Program Current E = V
IL
50 mA
V
IL
Input Low Voltage –0.3 0.8 V
V
IH
Input High Voltage 2.4 V
CC
+ 0.5 V
V
OL
Output Low Voltage I
OL
= 2.1mA 0.4 V
V
OH
Output High Voltage TTL I
OH
= –2.5mA 3.5 V
V
ID
A9 Voltage 11.5 12.5 V
Obsolete Product(s) - Obsolete Product(s)