IR25606SPBF
4 www.irf.com © 2013 International Rectifier May 1, 2013
Dynamic Electrical Characteristics
V
BIAS
(V
CC
, V
BS
) = 15V, CL = 1000 pF and T
A
= 25°C unless otherwise specified.
Turn-on propagation delay
ns
toff Turn-off propagation delay — 200 280
V
= 0V or 600V
DT Deadtime 400 540 680
MT Delay matching, HS & LS turn-on/off — 0 46
Static Electrical Characteristics
BIAS
(V
CC
, V
BS
) = 15V and T
A
= 25°C unless otherwise specified. The V
IN
, V
TH
and I
IN
parameters are
COM. The V
O
and I
O
parameters are referenced to COM and are applicable to the respective
V
V
OH
High level output voltage, V
BIAS
-
— 0.8 1.4
I
O
= 20 mA
Low level output voltage, V
O
Offset supply leakage current
μA
Quiescent V
BS
supply current
Quiescent V
CC
supply current
Logic “1” input bias current
μA
Logic “0” input bias current
V
CCUV+
V
CC
and V
BS
supply undervoltage
8 8.9 10
V
V
CCUV-
V
CC
and V
BS
supply undervoltage
7.4 8.2 9
V
CCUVH
Hysteresis 0.3 0.7 —
I
O+
Output high short circuit pulsed
current
97 200 —
mA
V
O
= 0V
I
O-
Output low short circuit pulsed
current
250 350 —
V
O
= 15V