JJN SERIES – DETECTOR SWITCHES
2331329-1 Rev A
06/2018
Dimensions in
millimetres unless
otherwise specified
Dimensions Shown for
reference purposes only.
Specifications subject to
change
For Email, phone
or live chat, go to:
www.te.com/help
Apply force in the direction of
operating stroke for 2.00mm
Fix the switch then apply a static load
of 0.3KgF to the tip of the terminal in
the desired direction for 1 minute
Shall be free from any
terminal damage and
looseness and breakage of
terminal holding position.
Terminal may be bent after
test, electrical performance
requirement specified in
item 4 shall be satisfied.
1) A static load of 1KgF shall be applied
in the operating direction of actuator
for 15 seconds.
2) A static load of 0.3KgF shall be
applied in the pulling direction of
actuator for 15 seconds. (For
construction with lock, the test shall be
conducted at the condition of lock
released)
3) A static load of 0.7KgF shall be
applied to the vertical direction of
operation at the tip of actuator for 15
seconds.
Shall be free from
mechanical and electrical
abnormalities.
Tested as follows:
50,000 cycles operations at a rate of 15
to 20 cycles/min without load.
(When pushing the actuator at right
angle)
1) Contact resistance:
150mΩ Min.
2) Insulation resistance:
10MΩ Min.
3) Voltage proof: Applying
100VAC for 1 minute, no
dielectric breakdown shall
occur.
4) Operating force: Within
30% of specified value.
5) No abnormalities shall be
recognised in appearance
construction.
After 5 cycles of following conditions,
the switch shall be allowed to stand
under normal temperature and
humidity condition for 1 hour and then
measurement shall be made within 1
hour after that.
Water drops shall be removed.
1) Contact resistance:
150mΩ Min.
2) Insulation resistance:
10MΩ Min.
3) Voltage proof: Applying
100VAC for 1 minute, no
dielectric breakdown shall
occur.
4) Operating force: Within
30% of specified value.
5) No abnormalities shall be
recognised in appearance
construction.