165
DC
DC Fan 120 mm sq.
The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers.
Model no.
Rated voltage
Operating voltage range
PWM duty
cycle*
[%]
Rated current
Rated input
Rated speed Max. airow
Max. static pressure
SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min
-1
]
[m³/min]
[CFM] [Pa] [inchH
²
O] [dB (A)] [˚C] [h]
9GA1212P4G001
12 10.2 to 13.8
100 0.93 11.16 6400 3.8 134 365 1.47 57
-
20 to
+
70
40000/60˚C
(70000/40˚C)
25 0.16 1.92 2550 1.5 53 60 0.24 34
9GA1212P4S001
100 0.61 7.32 5400 3.2 113 260 1.04 54
25 0.16 1.92 2550 1.5 53 60 0.24 34
9GA1224P4G001
24 20.4 to 27.6
100 0.47 11.28 6400 3.8 134 365 1.47 57
25 0.1 2.4 2550 1.5 53 60 0.24 34
9GA1224P4S001
100 0.31 7.44 5400 3.2 113 260 1.04 54
25 0.1 2.4 2550 1.5 53 60 0.24 34
9GA1248P4G001
48 40.8 to 53
100 0.24 11.52 6400 3.8 134 365 1.47 57
25 0.08 3.84 2550 1.5 53 60 0.24 34
9GA1248P4S001
100 0.16 7.68 5400 3.2 113 260 1.04 54
25 0.08 3.84 2550 1.5 53 60 0.24 34
* PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%.
Model no.
Rated voltage
Operating voltage range
Rated current
Rated input
Rated speed Max. airow Max. static pressure SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min
-1
]
[m³/min]
[CFM] [Pa] [inchH
²
O] [dB (A)] [˚C] [h]
9GA1212G4001
12 7 to 13.8
0.93 11.16 6400 3.8 134 365 1.47 57
-
20 to
+
70
40000/60˚C
(70000/40˚C)
9GA1212S4001
0.61 7.32 5400 3.2 113 260 1.04 54
9GA1224G4001
24 14 to 27.6
0.47 11.28 6400 3.8 134 365 1.47 57
9GA1224S4001
0.31 7.44 5400 3.2 113 260 1.04 54
9GA1248G4001
48 36 to 53
0.24 11.52 6400 3.8 134 365 1.47 57
9GA1248S4001
0.16 7.68 5400 3.2 113 260 1.04 54
Other sensor specications are available as options. Refer to the index (p. 553).
DC Fan
120
×
120
×
25 mm
San Ace 120 9GA type Low Power Consumption Fan
■ General Specications
・ Material ………………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
・ Expected life …………………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C,
rated voltage)
・ Motor protection function ………………… Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 529.
・ Dielectric strength …………………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
・ Insulation resistance ………………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
・ Sound pressure level (SPL) ……………… At 1 m away from the air inlet
・ Storage temperature ……………………… -30 to +70˚C (Non-condensing)
・ Lead wire ……………………………………… Red Black
Sensor
Yellow
Control
Brown
(For models without PWM control function, there is no speed control wiring.)
・ Mass ……………………………………………… 280 g
■ Specications
have ribs and pulse sensors with PWM control function.
For models without ribs, append "1" to the end of model numbers.