Spec. No. JENF243E-0009J-01 P4/ 10
MURATA MFG. CO., LTD.
Reference Only
9. Environmental Performance (It shall be soldered on the substrate.)
No. Item Specification Test Method
9.1 Temperature
Cycle
Meet table 3.
1 Cycle:
1 step :
- 40
°C (+ 0°C, - 3°C) / 30 minutes
2 step : Room Temperature / within 5 minutes
3 step :
+85 °C (+ 3°C, - 0°C)
/ 30 minutes
4 step : Room Temperature / within 5 minutes
Total of 10 cycles
Then measured after exposure in the room condition
for 4 to 48 hours.
Initial values: Then measured after heat treatment
(150°C (+0°C,-10°C), 1 hour) and exposure in the
room condition for 4 to 48 hours.
9.2 Humidity Temperature : 40 ± 2 °C
Humidity : 90 to 95 %(RH)
Time : 1000 h (+ 48h , - 0h)
Then measured after exposure in the room condition
for 4 to 48 hours.
9.3 Heat
Resistance
Temperature : 85 ± 2 °C
Time : 1000 h (+ 48h , - 0h)
Then measured after exposure in the room condition
for 4 to 48 hours.
9.4 Cold
Resistance
Temperature : -55 ± 2 °C
Time : 500 h (+ 24h , - 0h)
Then measured after exposure in the room condition
for 4 to 48 hours.
9.5 Humidity Load Temperature : 40 ± 2 °C
Humidity : 90 to 95 %(RH)
Test Voltage : Rated Voltage
Time : 500 h (+ 24h , - 0h)
Then measured after exposure in the room condition
for 4 to 48 hours.
9.6 Heat Life Temperature : 85 ± 3 °C
Test Voltage : Rated Voltage × 200%
Time : 1000 h (+ 48h , - 0h)
Charge Current: 10mA max.
Then measured after exposure in the room condition
for 4 to 48 hours.
10. Specification of Packaging
10.1. Appearance and Dimensions (8mm-wide plastic tape)
1.9±0.2
4.0±0.1
2.0±0.1
0.2±0.1
φ
1.5
3.6±0.2
3.5±0.05
1.75
±0.1
8.0±0.2
+0.1
-0
Direction of feed
4.0±0.1
2.0±0.05
(in mm)
Dimension of the Cavity is
measured at the bottom side.