1VAP2-6

CSM_1ZAP2_1VAP2_DS_E_3_2
1
Door Switches
1ZAP2/1VAP2
Door Switches with Built-in Basic
Switches for Long Life
• Installation in electrical facilities, equipment doors, and other
openings helps ensure safety by reliably preventing accidents.
• A Basic Switch if built in to provide a large switching capacity
and long service life.
Be sure to read Safety Precautions on page 3 and
Safety Precautions for All Basic Switches.
Ordering Information
Contact Form
Specifications
Note: 1. The 1VAP2-6 is also available with SPDT contacts. The model number
is 1VAP2-6 (V-15-1B6).
2. The built-in switch cannot be replaced.
Operation
Built-in Switch Model
Push
operation
Pull
operation
Self-reset Hold
Z-15GL42-B 1ZAP2
V-15-1B6
1VAP2-1
1VAP2-2
V-15-3B6 1VAP2-6
Model Name Contact form
1ZAP2
Double-throw
(SPDT)
1VAP2-1
1VAP2-2
1VAP2-6
Single-throw
(SPST-NO)
COM
NC
NO
COM NO
Item Model 1ZAP2 1VAP2-@
Built-in Switch Z-15GL42-B V-15-1B6/V-15-3B6
Rating
15 A, 125 VAC
(resistive load)
15 A, 250 V
(resistive load)
15 A, 125 VAC
(resistive load)
15 A, 250 V
(resistive load)
Ambient operating
temperature
25 to 80°C (with no icing or condensation)
Ambient operating
humidity
35% to 85%RH
Durability
Mechanical
100,000 operations min. 100,000 operations min.
Electrical 100,000 operations min. 25,000 operations min.
Degree of protection IP00
Electric shock
protection class
Class II
PTI
(proof tracking index)
175
Pollution degree 3 (IEC 947-5-1)
2
1ZAP2/1VAP2
Dimensions (Unit: mm)
沈み位置最大3.2
動作位置最小6.35
由位置最大11.1
6.4
11.1
11.1
±0.13
5.5± 0.4
1
10.7
± 0.4
Four, M4 × 0.7
#8-32UNC, Depth: 10
(unified screw thread)
19.5
Separator
5 6.4 dia. max.
78.6
6.35 dia.
34.9
7.1
25.4
±
0.13
16.7±
0.4
57.2
Z-15GL42-B
Three, M4x5.5 binding machine screws
Internal toothed washer
7.9
FP
1ZAP2
Operating
Characteristics
Model 1ZAP2
Operating force
Pretravel
Overtravel
OF max.
PT max.
OT min.
21.6 N
4.7 mm
3.2 mm
Free position FP max. 11.1 mm
Two, M3.5 holes
Two, M3.5
6.35 dia.
7.4 dia. max.
4.8 dia.
V-15-1B6 Basic Switch
Separator
Three, M3 × 0.5 × 3.2
round machine screws
with external toothed washers
13.2
40.6
(39.8)
33
±0.4
10.3±0.3
6.4
12.7
±0.2
6.8
6.7
±0.3
20.6±0.15
31±0.2
4.9
46
.
9
±0.3
5.5±0.2
FP
4.6
±0.3
1VAP2-1
1VAP2-1
OF max.
PT max.
OT min.
17.6 N
4.4 mm
2 mm
FP max. 9.5 mm
46.9± 0.3
31± 0.2
12.7
FP
4.9
4.8 dia.
7.4 dia. max.6.35 dia.
7.9
40.6
Two, M3
Three, M3 × 0.5 × 3.2
round machine screws
with external toothed washers
V-15-1B6 Basic Switch
Separator
38.1
± 0.2
46
19.1
± 0.2
8.7± 0.3
4.1
Three, M3 holes
6.4
12.7
1VAP2-2
1VAP2-2
OF max.
PT max.
OT min.
17.6 N
4.4 mm
2 mm
FP max.
9.5 mm
Mounting hole
FP
6.35 dia.
15
12 dia.
455866
4.2
± 0.2
P = 1 criss-cross
knurling
Stainless steel operation rod
V-15-3B6
Basic Switch
1
15.2
75.4
12
37
11
Cover (steel)
2
1.2
5
10
20
Two, 9-dia. lead wire
pullout holes
8
8
1VAP2-6
1VAP2-6
OF max.
PT max.
OT min.
14.7 N
6 mm
3 mm
FP max. 21 mm
Note: 1. The standard 1VAP2-6 has SPST-NO contacts.
2.
The 1VAP2-6 is also available with SPDT contacts. If SPDT contacts are required, order using the following model number. (The built-in switch is the V-15-1B6.)
1VAP2-6 (V-15-1B6)
3
1ZAP2/1VAP2
Safety Precautions
Refer to Safety Precautions for All Basic Switches.
Mounting Holes
Wiring
Tighten the terminal screws to the torque given in the following table.
Operating Environment
The Switch does not have a water-resistant structure. Take
measures to protect the Switch if it is to be used in locations subject
to splashing or spraying water or other liquids.
Do not use the Switch where it is continuously subjected to vibration
or shock. Doing so will result in contact failure, malfunction, or a
decrease in service life caused by abrasive powder that is
generated from the internal parts. Subjecting the Switch to
excessive vibration or shock may cause the contacts to
malfunction, stick, or become damaged. Make sure to install the
Switch in locations free of vibration or shock or in a direction where
resonance will not occur.
Do not use the Switch in locations subject to corrosive gas, such as
sulfuric gas (H
2S or SO2), ammonium gas (NH3), nitric gas (HNO3),
or chlorine gas (Cl
2), or high temperature and humidity.
Doing so will result in damage due to contact failure or corrosion.
If the Switch is used in locations with silicone gas, arc energy may
cause silicon dioxide (SiO
2) to build up on the contacts and contact
failure may result. If there is silicone oil, silicone sealant, or wire
covered with silicone close to the Switch, attach a contact
protective circuit to suppress the arcing of the Switch or eliminate
the source of silicone gas.
Use the switch within the specified range for operating temperature
and humidity. Using the Switch in high temperatures will cause the
operating characteristics to deviate. Rapid changes in temperature
will also cause the operating characteristics to deviate. It is
recommended to install the Switch as far as possible from heat
sources so that the temperature of the Switch is not affected.
Precautions for Correct Use
Mounting
direction
1ZAP2 1VAP2-1 1VAP2-2 1VAP2-6
Front mounting
Side mounting (Side mounting is not possible)
25.4
±
0.3
Two, 4.5 dia. holes
+0.3
0
20.6 ± 0.3
Two, 4 dia. holes
+0.3
0
38.1± 0.3
Two, 3.5 dia. holes
+0.3
0
58± 0.3
37± 0.3
0.3
0
Four, M4 or 4.5 dia. holes
11.1
±
0.3
11.1
±
0.3
10 dia. min.
Two, 4.5 dia. holes
+0.3
0
10.3± 0.3
12.7± 0.3
10 dia. min.
Two, 4 dia. holes
+0.3
0
± 0.3
8.7
38.1
± 0.3
19.1± 0.3
Two, 3.5 dia. holes
+0.3
0
10 dia. min.
1ZAP2 1VAP2
0.78 to 1.78 N·m 0.19 to 0.29 N·m

1VAP2-6

Mfr. #:
Manufacturer:
Description:
Basic / Snap Action Switches SWITCH
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union