66L060

6600, 6700
http://airpax.sensata.com/
6600 Series 40
SPECIFICATIONS
Contact Resistance 50 milliohms max (before and after rated life)
Contact Ratings Cycles Voltage Amps (resistive)
25,000 48 VDC 1.0
30,000 120 VAC 1.0
100,000 5 VDC 0.020 (gold)
Contact Operations Either close on rise (make) or open on rise (break)
Operating Temperature 40°C to 130°C (104°F to 266°F)
Temperature Tolerance
Standard of ±5°C (±9°F) with nominal operating temperature settings in 5°C increments
Short Term / Long Term
Exposure Limit
Short = 260°C (500°F), 10 second duration Long = -55°C to 160°C (-67°F to 320°F)
Dielectric Strength 1480 VAC 60Hz, 1 second duration terminals to case
Insulation Resistance 100 Mohms at 500 VDC
Contact Bounce 3 milliseconds max (make)
Vibration Per Mil-Std-202, method 204D, test condition D, 10 to 2,000 Hz
Shock Per Mil-Std-202, method 213, test condition C, 100 G’s for 6 millisecond duration, ½ sine wave
Seal High temperature epoxy sealed for wave soldering and cleaning, moisture proof per Sensata
specification S-722 (unit will not leak while submerged in 9” of water for a minimum of two minutes)
Base Material PPS (Polyphenylene Sulfide), 94 VO rated
Terminal Material 65% Copper, 18% Nickel
Contact Material Gold-plated or overlay, silver crossbar
Chemical Resistance Unit is resistance to water, salt, alcohol, ammonia, trichlorethane and most other organic solvents
Soldering Heat
Resistance
Per Mil-Std-202F, method 210A, test condition E
Weight Approximately 0.45 grams
Mechanical Life 1,000,000 operations
Agency Approvals cЯUus recognized E36687
VDE approval 0631/12.83
RoHS Compliant per EU Directive 2002/95/EC
FEATURES
• Gold-platedcontacts
• 30,000lifecycles@maxstandardamperage
• 100,000lifecycles@maxgoldcontactamperage
• RoHScompliantperEUdirective2002/95/EC
• 8-pinDIPinternationalelectronicpackagestandard
• IdealforsurfaceandairsensingonPCboards
DESCRIPTION
The Airpax™ 6600 series is a RoHS compliant, positive snap action, single pole / single throw, sub-miniature bimetallic thermostat
which provides accurate and reliable sensing and switching in a single device.
The 6600 series thermostat dimensionally conforms to the international product package standard 8-pin DIP (N8A Dual Inline Package).
The 6600 is ideally suited for use on printed circuit boards. Its size and shape conserves space on crowded PC boards and can be
installed using auto-insertion equipment. The device is sealed to withstand wave soldering and board washing operations.
The 6600 provides fast, positive response with excellent repeatability. The thermostat has a switch capability of up to 1 amp for 48 VDC
or 120 VAC for 30,000 cycles, and achieves low-level switching down to 0.001 A to 0.020 A at 5 VDC for 100,000 cycles. Temperature is
pre-set at the factory and is non-adjustable in the field.
Applications include computers and computer peripherals, aircraft, automotive and test equipment. Typical uses include turning on an
indicator light, sounding an audible alarm, switch on a control circuit to send a message to a display screen or even switching a circuit
to shut down a system.
The 6600 thermostat is temperature tested in a computer controlled automated test equipment air-oven. Due to the ideal conditions
under which it is tested, independent customer testing may be necessary to ensure that the correct calibration is utilized in the
application.
It is the customer’s responsibility to determine whether the product is proper for customer’s use and application.
6600 Series
8-PIN DIP BIMETAL DISC THERMOSTAT
http://airpax.sensata.com/
6600 Series
39
OPERATION SCHEMATICS
Schematic for
Open on Rise
Operation
Schematic for
Close on Rise
Operation
6600, 6700
http://airpax.sensata.com/
6600 Series 42
http://airpax.sensata.com/
6600 Series
41
DIMENSIONAL SPECIFICATIONS, inches [mm]
Standard 8-Pin DIP Configuration
DECISION TABLES
Epoxy Seal
Epoxy Seal
0.300 ± 0.005
(7.62 ± 0.13)
0.018 ± 0.003
(0.46 ± 0.08)
0.050 ± 0.005
(1.27 ± 0.13)
0.325 ± 0.025
(8.26 ± 0.64)
0.010 ± 0.005
(0.250 ± 0.013)
0.250 ± 0.005
(6.35 ± 0.13)
+0.25
-0.13
-0.005
(3.30 )
+0.010
0.130
R0.018
REF
(R0.46)
R0.010
REF
(R0.25)
0.050 ± 0.005
(1.27 ± 0.13)
0.010 ± 0.005
(0.25 ± 0.13)
0.300 ± 0.010
(7.62 ± 0.25)
0.250 ± 0.005
(6.35 ± 0.13)
0.040 ± 0.005
(1.02 ± 0.13)
0.225 ± 0.003
(5.72 ± 0.08)
0.450 ± 0.010
(11.43 ± 0.25)
0.125
MIN
(3.18)
0.035
MIN
(0.89)
0.033
MIN
(0.84)
0.400 ± 0.005
(10.16 ± 0.13)
0.050 ± 0.005
(1.27 ± 0.13)
0.018 ± 0.003
(0.46 ± 0.08)
0.300 ± 0.010
(7.62 ± 0.25)
0.400 ± 0.005
(10.16 ± 0.13)
+0.25
-0.13
-0.005
(3.30 )
+0.010
0.130
Basic Product Series
Contact Operation
F = Fan (close on rise)
L = Limit (open on rise)
Operating Temperature
in °C, 3 digits (from above table, put “0” in front of 2 digit temps)
Factory Assigned Number
Nondescript, 4 digit dash number assigned for a
customer’s special requirements
66 F 0 9 5 5 5 8 8
Epoxy Seal
Epoxy Seal
0.300 ± 0.005
(7.62 ± 0.13)
0.018 ± 0.003
(0.46 ± 0.08)
0.050 ± 0.005
(1.27 ± 0.13)
0.325 ± 0.025
(8.26 ± 0.64)
0.010 ± 0.005
(0.250 ± 0.013)
0.250 ± 0.005
(6.35 ± 0.13)
+0.25
-0.13
-0.005
(3.30 )
+0.010
0.130
R0.018
REF
(R0.46)
R0.010
REF
(R0.25)
0.050 ± 0.005
(1.27 ± 0.13)
0.010 ± 0.005
(0.25 ± 0.13)
0.300 ± 0.010
(7.62 ± 0.25)
0.250 ± 0.005
(6.35 ± 0.13)
0.040 ± 0.005
(1.02 ± 0.13)
0.225 ± 0.003
(5.72 ± 0.08)
0.450 ± 0.010
(11.43 ± 0.25)
0.125
MIN
(3.18)
0.035
MIN
(0.89)
0.033
MIN
(0.84)
0.400 ± 0.005
(10.16 ± 0.13)
0.050 ± 0.005
(1.27 ± 0.13)
0.018 ± 0.003
(0.46 ± 0.08)
0.300 ± 0.010
(7.62 ± 0.25)
0.400 ± 0.005
(10.16 ± 0.13)
+0.25
-0.13
-0.005
(3.30 )
+0.010
0.130
Surface Mount (Gullwing, SMT) Configuration
STANDARD PACKAGING
Standard and surface mount samples and production orders will be shipped in plastic, industry standard DIP shipping tubes.
THROUGH BOTH WALLS
0.250
REF
(6.35)
0.250
REF
(6.35)
Ø0.125 ± 0.002
(Ø3.18 ± 0.05)
21.000 ± 0.062
(533.40 ± 1.19)
0.025
TYP WALL
(0.64)
0.285 ± 0.010
(7.24 ± 0.25)
0.160
(4.06)
0.275 ± 0.025
(6.99 ± 0.64)
0.070
(1.78)
0.160 ± 0.020
(4.06 ± 0.51)
0.550
(13.97)
R0.031
REF
(R0.79)
0.090
(2.29)
OPERATE (±5°C) MIN DIFFERENTIAL (°C) MIN RESET (°C)
40 4 20
45 4 20
50 4 30
55 4 30
60 4 40
65 4 40
70 4 50
75 4 50
80 6 55
85 6 55
90 6 60
95 6 60
100 6 70
105 6 70
110 6 80
115 6 85
120 9 90
125 9 90
130 9 90
STANDARD TEMPERATURE CALIBRATION TABLE
Each thermostat part number consists of functional
“building blocks” to enable the user to specify clearly
and precisely the desired characteristics in each
category. Select the proper code in each category,
then transfer it to the box indicated. Unless a special
requirement is indicated, the part number will be
complete when the proper temperature is selected. If
you have a special requirement, please call Sensata for
a factory assigned number to complete the part number.
Example :
A 66F095 thermostat will close (make contact) on a rising
temperature from 90°C to 100°C and will reset open
(break contact) on a falling temperature within a window
of no greater than 6°C lower than the actual close
temperature and no less than 60°C ambient temperature.
Special requirements require a 4 digit manufacturing
dash number for ordering special features, 4 digit
marking may not appear as part of the marking on the
thermostat.
Special requirements may include VDE, ±3.0°C (±5.4°F)
operating temperature tolerance, or surface mount
(gullwing, SMT).
Temperature set point calibration is checked at Sensata
Technologies with precision test equipment traceable to
the US National Institute of Standards and Technology
and Proven Methods. Because customer checking
methods may differ, a typical variance allowed for
correlation is ±1.1°C (±2.0°F).

66L060

Mfr. #:
Manufacturer:
Description:
Bimetal Disc Thermostat Automotive - 8 lead Mini-DIP package w/4 leads
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: