Power Up and Down Requirements
The are no restrictions on the power-up or power-down conditions of V
CC
and the voltages applied to the potentiometer pins
provided that V
CC
is always more positive than or equal to V
H
, V
L
, and V
W
, i.e., V
CC
V
H
, V
L
, V
W
. The V
CC
ramp rate spec is
always in effect.
NOTES:
1. Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage = (V
w(n)
(actual)–V
w(n)
(expected)) = ±1 Ml Maximum.
2. Relative Linearity is a measure of the error in step size between
taps = V
W
(n+1)
– [V
w(n)
+ Ml] = ±0.2 Ml.
3. 1 Ml = Minimum Increment = R
TOT
/31.
4. Typical values are for T
A
= +25°C and nominal supply voltage.
5. This parameter is periodically sampled and not 100% tested.
Absolute Maximum Ratings Operating Conditions
Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS
, INC, U/D, V
H
, V
L
and
V
CC
with respect to V
SS
. . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
V = |V
H
–V
L
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V
Lead temperature (soldering 10s) . . . . . . . . . . . . . . . . . . . . . +300°C
I
W
(10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±7.5mA
Temperature Range
Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage (V
CC
)
X9015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10%
X9015-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Potentiometer Specifications Over recommended operating conditions unless otherwise stated
SYMBOL PARAMETER TEST CONDITIONS/NOTES MIN. TYP. MAX. UNIT
R
TOTAL
End to End Resistance Variation –20 +20 %
V
VH
V
H
/R
H
Terminal Voltage 0 V
CC
V
V
VL
V
L
/R
L
Terminal Voltage 0 V
CC
V
Power Rating R
TOTAL
1k 10 mW
R
W
Wiper Resistance I
W
= 1mA, V
CC
= 5V 200 400
R
W
Wiper Resistance I
W
= 1mA, V
CC
= 2.7V 400 1000
I
W
Wiper Current -3.75 3.75 mA
Noise Ref: 1kHz -120 dBV
Resolution 3%
Absolute Linearity (Note 1) V
w(n)(actual)
–V
w(n)(expected)
-1 +1 MI (Note 3)
Relative Linearity (Note 2) V
w(n+1)
–[V
w(n)+MI
] -0.2 +0.2 MI (Note 3)
R
TOTAL
Temperature Coefficient ±300 ppm/°C
Ratiometric Temperature Coefficient ±20 ppm/°C
C
H
/C
L
/C
W
Potentiometer Capacitances See circuit #3 10/10/25 pF
X9015
5
FN8157.6
August 14, 2015
)
Symbol Table
D.C. Operating Specifications Over recommended operating conditions unless otherwise specified
SYMBOL PARAMETER TEST CONDITIONS MIN.
TYP.
(Note 4) MAX. UNITS
I
CC1
V
CC
active current (increment) CS = V
IL
, U/D = V
IL
or V
IH
and
INC
= 0.4V @ max. t
CYC
50 µA
I
CC2
V
CC
active current (Store) (EEPROM
Store)
CS = V
IH
, U/D = V
IL
or V
IH
and
INC
=V
IH
@ max. t
WR
400 µA
I
SB
Standby supply current CS = V
CC
– 0.3V, U/D and
INC
=V
SS
or V
CC
– 0.3V
A
I
LI
CS, INC, U/D input leakage current V
IN
= V
SS
to V
CC
±10 µA
V
IH
CS, INC, U/D input HIGH voltage V
CC
x 0.7 V
CC
+ 0.5 V
V
IL
CS, INC, U/D input LOW voltage -0.5 V
CC
x 0.1 V
C
IN
(Note 5) CS, INC, U/D input capacitance V
CC
= 5V, V
IN
= V
SS
, T
A
= 25°C,
f= 1MHz
10 pF
TEST CIRCUIT #1 TEST CIRCUIT #2 CIRCUIT #3 SPICE MACRO MODEL
Test Point
V
W
/R
W
V
H
/R
H
V
L
/R
L
V
S
Force
Current
V
L
VW
Test Point
V
H
/R
H
V
W
/R
W
V
L
/R
L
C
H
C
L
R
W
10pF
10pF
R
H
R
L
R
TOTAL
C
W
25pF
A.C. Conditions of Test
Input pulse levels 0V to 3V
Input rise and fall times 10ns
Input reference levels 1.5V
WAVEFORM INPUTS OUTPUTS
Must be
steady
Will be
steady
May change
from Low to
High
Will change
from Low to
High
May change
from High to
Low
Will change
from High to
Low
Don’t Care:
Changes
Allowed
Changing:
State Not
Known
N/A Center Line
is High
Impedance
X9015
6
FN8157.6
August 14, 2015
A.C. Timing
A.C. Operating Specifications Over recommended operating conditions unless otherwise specified
SYMBOL PARAMETER MIN. TYP. (Note 6) MAX. UNIT
t
Cl
CS to INC setup 100 ns
t
lD
INC HIGH to U/D change 100 ns
t
DI
U/D to INC setup 2.9 µs
t
lL
INC LOW period 1 µs
t
lH
INC HIGH period 1 µs
t
lC
INC inactive to CS inactive 1 µs
t
CPH
CS deselect time (NO STORE) 100 ns
t
CPH
CS deselect time (STORE) 10 ms
t
IW
INC to Vw change 1 5 µs
t
CYC
INC cycle time 4 µs
t
R,
t
F
(Note 7) INC input rise and fall time 500 µs
t
PU
(Note 7) Power up to wiper stable s
t
R
V
CC
(Note 7) V
CC
power-up rate 0.2 50 V/ms
t
WR
Store cycle 5 10 ms
CS
INC
U/D
V
W
t
CI
t
IL
t
IH
t
CYC
t
ID
t
DI
t
IW
MI
(8)
t
IC
t
CPH
t
F
t
R
10%
90% 90%
(store)
NOTES:
6. Typical values are for T
A
= +25°C and nominal supply voltage.
7. This parameter is periodically sampled and not 100% tested.
8. MI in the A.C. timing diagram refers to the minimum incremental change in the V
W
output due to a change in the wiper position.
X9015

X9015UM8IZ-2.7

Mfr. #:
Manufacturer:
Renesas / Intersil
Description:
Digital Potentiometer ICs VOLATILE XDCP 50K 32 TAPS U/D 8LD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: