SpecNo.JELF243A-9140B-01 P1/8
MURATA MFG.CO., LTD
Reference Only
CHIP COIL (CHIP INDUCTORS) LQH3NPZ□□□□MEL SPECIFICATION
Murata Standard Reference Specification【AEC-Q200】
1.Scope
This reference specification applies to Chip coil (Chip Inductors) LQH3NPZ_ME series for Automotive Electronics based
on AEC-Q200 except for Power train and Safety.
2.Part Numbering
(ex) LQ H 3N P Z 1R0 M M E L
Product ID Structure Dimension Applications Category Inductance Tolerance Dimension Others Packaging
(L×W) and (T) L: Φ180Taping
Characteristics
3.Rating
・Operating Temperature Range.
(Ambient temperature; Self-temperature rise is not included) -40 to +105°C
(Product temperature; Self- temperature rise is included) -40 to +125°C
・Storage Temperature Range.
-40 to +125°C
Customer
Part Number
Murata
Part Number
Inductance
DC
Resistance
(Ω)
Self
Resonant
Frequency
(MHz min)
Rated Current(mA)
ESD
2: 2kV
∗1 Based on
inductance
change
∗2 Based on
Temperature rise
(µH)
Tolerane
(%)
∗3 Ambient
temperature
(85 )℃
∗4 Ambient
temperature
(105 )℃
LQH3NPZ1R0MMEL 1.0
M:±20%
0.025±20% 100 2350 3000 1600
2
LQH3NPZ2R2MMEL 2.2 0.065±20% 60 1800 2100 1220
LQH3NPZ3R3MMEL 3.3 0.084±20% 55 1520 1900 1150
LQH3NPZ4R7MMEL 4.7 0.10±20% 40 1300 1700 1000
LQH3NPZ6R8MMEL 6.8 0.14±20% 30 1040 1450 900
LQH3NPZ100MMEL 10 0.19±20% 20 810 1280 800
LQH3NPZ150MMEL 15 0.29±20% 15 660 1020 620
LQH3NPZ220MMEL 22 0.40±20% 10 570 860 540
LQH3NPZ330MMEL 33 0.55±20% 8 440 760 460
LQH3NPZ470MMEL 47 0.82±20% 5 380 610 380
LQH3NPZ560MMEL 56 1.0±20% 5 350 500 320
LQH3NPZ680MMEL 68 1.15±20% 5 310 470 300
LQH3NPZ101MMEL 100 1.59±20% 3 260 430 270
∗1:When applied Rated current to the Products , Inductance will be within ±30% of initial inductance value range.
∗2:Keep the temperature (ambient temperature plus self-generation of heat) under 125 . ℃
∗3:When applied Rated current to the Products ,temperature rise caused by self-generated heat shall be limited to 40 ℃
max. (Ambient temperature 85 ).℃
∗4:When applied Rated current to the Products ,temperature rise caused by self-generated heat shall be limited to
20 max.℃ (Ambient temperature 85 to 105 ).℃
4. Testing Conditions
《Unless otherwise specified》 《In case of doubt》
Temperature : Ordinary Temperature (15 to 35°C) Temperature : 20C± 2°C
Humidity : Ordinary Humidity (25 to 85 %(RH) Humidity : 60 to 70%(RH)
Atmospheric Pressure : 86 to 106 kPa