2010 Microchip Technology Inc. DS22271A-page 9
RE46C190
Smoke Test Period
with Continuous Horn
Pattern
T
PER0B
2 10 10.7 11.4 s Standby, no alarm
T
PER1B
2 2.5 2.7 2.9 s Standby, after one valid
smoke sample
T
PER2B
2 1.25 1.33 1.41 s Standby,
after two consecutive
valid smoke samples
T
PER3B
2 1.251.331.41 sLocal Alarm
(three consecutive valid
smoke samples)
T
PER4B
2 313 333 353 ms Push button test
T
PER5B
2 10 10.7 11.4 s In remote alarm
Chamber Test Period T
PCT1
2 40 43 46 s Standby, no alarm
Long Term Drift
Sample Period
T
LTD
2 400 430 460 s Standby, no alarm
LTD enabled
Low Battery
Low Battery Sample
Period
T
PLB1
3 320 344 368 s RLED on
T
PLB2
3808692 sRLED on
Horn Operation
Low Battery Horn
Period
T
HPER1
13 40 43 46 s Low battery, no alarm
Chamber Fail Horn
Period
T
HPER2
13 40 43 46 s Chamber failure
Low Battery Horn
On Time
T
HON1
13 9.8 10.4 11.0 ms Low battery, no alarm
Chamber Fail Horn
On Time
T
HON2
13 9.8 10.4 11.0 ms Chamber failure
Chamber Fail
Off Time
T
HOF1
13 305 325 345 ms Failed chamber,
no alarm, 3x chirp option
Alarm On Time
with Temporal Horn
Pattern
T
HON2A
13 470 500 530 ms Local or remote alarm
(Note 1)
Alarm Off Time
with Temporal Horn
Pattern
T
HOF2A
13 470 500 530 ms Local or remote alarm
(Note 1)
T
HOF3A
13 1.4 1.5 1.6 s Local or remote alarm
(Note 1)
Alarm On Time
with Continuous
Horn Pattern
T
HON2B
13 235 250 265 ms Local or remote alarm
(Note 1)
Alarm Off Time
with Continuous
Horn Pattern
T
HOF2B
13 78 83 88 ms Local or remote alarm
(Note 1)
AC ELECTRICAL CHARACTERISTICS (CONTINUED)
AC Electrical Characteristics: Unless otherwise indicated, all parameters apply at T
A
= -10° to +60°C, V
DD
= 3V,
V
BST
= 4.2V, Typical Application (unless otherwise noted) (Note 1 to Note 4).
Parameter Symbol Test Pin Min Typ Max Units Condition
Note 1: See timing diagram for Horn Pattern (Figure 5-2).
2: T
PCLK
and T
IRON
are 100% production tested. All other AC parameters are verified by functional testing.
3: Typical values are for design information only.
4: Limits over the specified temperature range are not production tested, and are based on characterization
data.