Technical Data Sheet
RPC-2.92 Airline Plug / Jack
02S101-K018
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2 / 3
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Electrical data
Insertion loss ≤ 0.15 dB at 40 GHz
Mechanical data
Mating cycles ≥ 500
Maximum torque 1.70 Nm
Recommended torque 0.90 Nm
Airline dimensions at 23 °C:
- Diameter outer conductor 2.9235 mm ± 0.005 mm
- Diameter inner conductor 1.270 mm ± 0.005 mm
- Length outer conductor 18.30 mm + 0.02 mm
- Length inner conductor 18.30 mm - 0.02 mm
- Length difference ≤ 0.04 mm
(outer conductor – inner conductor)
Calculated data (non warranted)
Lossless characteristic impedance
1
50 Ω ± 0.40 Ω
Return loss
2
≥ 38 dB, 0.3 GHz to 4 GHz
≥ 35 dB, 4 GHz to 18 GHz
≥ 30 dB, 18 GHz to 40 GHz
1. The lossless characteristic impedance is calculated from the specified diameters of the inner and outer conductor.
2. The return loss is calculated from the characteristic impedance, the skin depth and the connector interface.
General standard definitions
For proper work the vector network analyzer (VNA) used needs a model describing the electrical behaviour
of this calibration standard. Depending on the VNA type different models, units and terms are used
and have to be entered into the VNA. All values are based on typical geometry and plating.
- Offset Z
o
/ Impedance / Z
o
50 Ω
- Offset Delay 61.095 ps
- Length (electrical) / Offset Length 18.316 mm
- Offset Loss 2.40 GΩ/s
- Loss 0.0127 dB/
Environmental data
Operating temperature range
3
+20 °C to +26 °C
Storage temperature range 0 °C to +50 °C
RoHS compliant
3. This range is a recommendation. However, the airline can be used in a wider range.
Any temperature change from 23 °C results in dimensional changes.