8
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics (HCNW4502/3 ONLY)
Description Symbol Characteristic Units
Installation classication per DIN VDE 0110/39, Table 1
for rated mains voltage ≤600 V rms I-IV
for rated mains voltage ≤1000 V rms I-III
Climatic Classication 55/85/21
Pollution Degree (DIN VDE 0110/39) 2
Maximum Working Insulation Voltage V
IORM
1414 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec, V
PR
2652 V
peak
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and sample test, V
PR
2262 V
peak
t
m
= 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 60 sec) V
IOTM
8000 V
peak
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
Case Temperature T
S
150 °C
Input Current I
S,INPUT
400 mA
Output Power P
S,OUTPUT
700 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥ 10
9
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics (OPTION 060 ONLY)
Characteristic
Description Symbol HCPL-4502/4503 HCPL-0452/0453 Units
Installation classication per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 300 V
rms
I-IV I-IV
for rated mains voltage ≤ 600 V
rms
I-IV I-I I I
Climatic Classication 55/100/21 55/100/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
630 560 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec, V
PR
1181 1050 V
peak
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and sample test, V
PR
1008 896 V
peak
t
m
= 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 60 sec) V
IOTM
8000 6000 V
peak
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
Case Temperature T
S
175 175 °C
Input Current I
S,INPUT
230 150 mA
Output Power P
S,OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥10
9
≥10
9
Ω