TP-75C

SPECIFICATION
TP-75A TP-75B TP-75C
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
5V
CH1
12V
CH2
-5V
CH3
5V
CH1
12V
CH2
-12V
CH3
5V
CH1
15V
CH2
-15V
CH3
7A 3A 0.6A 7A 3A 0.4A 6A 2.5A 0.5A
1.5 ~ 10A 0.2 ~ 4A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 4A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 3A 0 ~ 0.6A
74W 75.8W 75W
100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p
±3.0% ±3.0% ±3.0%
±3.0% ±3.0% ±3.0%
CH1: 4.75 ~ 5.5V
±4.0% ±4.0% ±4.0%
±4.0% ±4.0% ±4.0%
±8.0% ±8.0% ±8.0%
±8.0% ±8.0% ±8.0%
±1.0% ±1.0% ±1.0%±1.0% ±1.0% ±1.0%±1.0% ±1.0% ±1.0%
800ms, 60ms at full load
36ms at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.97/115VAC at full load
70%
1.5A/115VAC 0.8A/230VAC
COLD START 20A/230VAC
<2mA / 240VAC
105 ~ 150% rated output power
5.75 ~ 6.75V on +5V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1 approved
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH non-condensing
±℃
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
198.4K hrs min. MIL-HDBK-217F (25 )
179*99*33mm (L*W*H)
0.65Kg; 20pcs/12.7Kg/0.64CUFT
75W Triple Output with PFC Function
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Low profile: 33mm thickness
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
Features :
TP-75 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
OUTPUT NUMBER
File Name:TP-75-SPEC 2017-12-05
EMC IMMUNITY
EMC EMISSION
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
SPECIFICATION
TP-75D TP-7503
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
5V
CH1 CH1
24V
CH2 CH2
12V
CH3 CH3
5V 3.3V 12V
7A 1.5A 0.4A 9A 8A 0.3A
1.5 ~ 10A 0.2 ~ 2.5A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 8A 0 ~ 0.6A
75.8W 75W
100mVp-p 120mVp-p 120mVp-p 100mVp-p 50mVp-p 120mVp-p
±3.0% ±3.0%
±3.0% ±3.0%
CH1: 4.75 ~ 5.5V
±4.0% ±4.0%
±4.0% ±4.0%
±8.0% ±8.0%
±8.0% ±8.0%
±1.0% ±1.0%±1.0% ±1.0%±1.0% ±1.0%
800ms, 60ms at full load
36ms at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.97/115VAC at full load
70%
1.5A/115VAC 0.8A/230VAC
COLD START 20A/230VAC
<2mA / 240VAC
105 ~ 150% rated output power
5.75 ~ 6.75V on +5V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1 approved
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH non-condensing
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
198.4K hrs min. MIL-HDBK-217F (25 )
179*99*33mm (L*W*H)
File Name:TP-75-SPEC 2017-12-05
75W Triple Output with PFC Function
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload/ Over voltage
Low profile: 33mm thickness
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
Features :
TP-75 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
0.65Kg; 20pcs/12.7Kg/0.64CUFT
OUTPUT NUMBER
EMC IMMUNITY
EMC EMISSION
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
Mechanical Specification
Derating Curve Output Derating VS Input Voltage
File Name:TP-75-SPEC 2017-12-05
Case No. 920A Unit:mm
AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz
85 100 115 125 155 230 264
LOAD (%)
LOAD (%)
10 20 30 40 50 60 70
20
40
60
80
100
-10 0
(HORIZONTAL)
90
100
80
70
60
50
40
With 18CFM
Forced AIR
(15cm)
Convection
TP-75 series
75W Triple Output with PFC Function
Block Diagram
PFC fosc : 67KHz
PWM fosc : 134KHz
PWM & PFC
CIRCUIT
DETECTION
O.L.P.
EMI FILTER
RECTIFIERS
CIRCUIT
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
&
PFC
CONSTANT
CURRENT
LIMITING &
Terminal Pin No. Assignment
Pin No.Pin No.
7
6
8
AssignmentAssignment
AC/N
DC OUTPUT +V2
AC/L
COM
DC OUTPUT +V1
DC OUTPUT +V3
FG
1
2,3
4
5
+ADJ.
LED
6.15
7.62
4
8
6
7
55
2
3
1
16
15
119
179
117
25
33
6-M4 L=6mm
32.5
17
18
8
60 65
2-M4 L=4mm
49.5
99
9 max.

TP-75C

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 75W 5V/6A 15V/2.5A -15V/0.5A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet