MC100EL1648
http://onsemi.com
4
Table 4. PECL DC CHARACTERISTICS V
CC
= 5.0 V; V
EE
= 0.0 V +0.8 / −0.5 V (Note 2)
Symbol
Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
I
EE
Power Supply Current 13 19 25 13 19 25 13 19 25 mA
V
OH
Output HIGH Voltage (Note 3) 3950 4170 4610 3950 4170 4610 3950 4170 4610 mV
V
OL
Output LOW Voltage (Note 3) 3040 3410 3600 3040 3410 3600 3040 3410 3600 mV
AGC Automatic Gain Control Input 1690 1980 1690 1980 1690 1980 mV
V
BIAS
Bias Voltage (Note 4) 1650 1800 1650 1800 1650 1800 mV
V
IL
1.5 1.35 1.2 V
V
IH
2.0 1.85 1.7 V
I
L
Input Current −5.0 −5.0 −5.0 mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. Output parameters vary 1:1 with V
CC
.
3. 1.0 MW impedance.
4. This measurement guarantees the dc potential at the bias point for purposes of incorporating a varactor tuning diode at this point.
Table 5. NECL DC CHARACTERISTICS V
CC
= 0.0 V; V
EE
= −5.0 V +0.8 / −0.5 V (Note 5)
Symbol
Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
I
EE
Power Supply Current 13 19 25 13 19 25 13 19 25 mA
V
OH
Output HIGH Voltage (Note 6) −1050 −830 −399 −1050 −830 −399 −1050 −830 −399 mV
V
OL
Output LOW Voltage (Note 6) −1960 −1590 −1400 −1960 −1590 −1400 −1960 −1590 −1400 mV
AGC Automatic Gain Control Input −3310 −3020 −3310 −3020 −3310 −3020 mV
V
BIAS
Bias Voltage (Note 7) −3350 −3200 −3350 −3200 −3350 −3200 mV
V
IL
−3.5 −3.65 −3.8 V
V
IH
−3.0 −3.15 −3.3 V
I
L
Input Current −5.0 −5.0 −5.0 mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
5. Output parameters vary 1:1 with V
CC
.
6. 1.0 MW impedance.
7. This measurement guarantees the dc potential at the bias point for purposes of incorporating a varactor tuning diode at this point.