HVG-100-20B

100W Constant Voltage + Constant Current LED Driver
HVG-100 series
Description
Wide input range 180 ~ 528VAC
Constant Voltage + Constant Current mode output
Metal housing with Class design
Built-in active PFC function
Class 2 power unit
IP67 / IP65 rating for indoor or outdoor installations
Function options: output adjustable via potentiometer;
3 in 1 dimming (dim-to-off); Timer dimming
Typical lifetime>50000 hours
5 years warranty
LED street lighting
LED high-bay lighting
Parking space lighting
LED fishing lamp
LED greenhouse lighting
Type HL for use in Class , Division 2
hazardous (Classified) location.
Features Applications
D IP67 Built-in Smart timer dimming function by user request. By request
IP65 IP67
Type HL
HVG-100 series is a 100W AC/DC LED driver featuring the dual mode constant voltage and constant
current output. HVG-100 operates from VAC and offers models with different rated voltage180~528
ranging between 15V and 54V. Thanks to the high efficiency up to 91%, with the fanless design, the
entire series is able to operate for -40 ~ +90 case temperature under free air convection. The design℃℃
of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor
applications. HVG-100 is equipped with various function options, such as dimming methodologies, so as
to provide the optimal design flexibility for LED lighting system.
Model Encoding
-20HVG - 100
A
Rated output voltage(15/20/24/30/36/42/48/54V)
Rated wattage
Series name
Function options
Type
A
B
IP Level
IP65
IP67
Io and Vo adjustable through built-in potentiometer.
3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance)
Function Note
In Stock
In Stock
File Name:HVG-100-SPEC 2018-05-29
AB IP65
3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance)
Io and Vo adjustable through built-in potentiometer &
In Stock
SPECIFICATION
100W Constant Voltage + Constant Current LED Driver
HVG-100 series
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
47 ~ 63Hz
0.38A / 347VAC 0.28A / 480VAC
<0.75mA / 480VAC
95 ~ 108%
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
174.9K hrs min. MIL-HDBK-217F (25 )
236*68*38.8mm (L*W*H)
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
SHORT CIRCUIT
18 ~ 21V
28 ~ 34V23 ~ 27V
34 ~ 38V
41 ~ 46V 54 ~ 60V
47 ~ 53V 59 ~ 65V
89%
91%
91% 91%90.5% 91%
±2.0% ±1.0% ±1.0% ±1.0%
±1.0%
±1.0%
±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±1.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
15V
HVG-100-15 HVG-100-20 HVG-100-24 HVG-100-30 HVG-100-36 HVG-100-42 HVG-100-48 HVG-100-54
24V 30V 48V
150mVp-p 150mVp-p
13.5 ~ 17V 17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
200mVp-p
43 ~ 53V
54V
200mVp-p
49 ~ 58V
42V
200mVp-p
38 ~ 46V
Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
Shut down o/p voltage with auto-recovery or re-power on to recovery
2.75 ~ 5A 2.64 ~ 4.8A 2.2 ~ 4A 1.76 ~ 3.2A
1.45 ~ 2.65A
1.1 ~ 2A 0.97 ~ 1.77A
1.25 ~ 2.28A
5A
3.2A
2.65A
2A
75W 96W 96W
95.4W
96W
1.77A
95.58W
2.28A
95.76W
1.18Kg
; 12pcs/15.2Kg/0.74CUFT
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
UL8750(type”HL”), CSA C22.2 No. 250.0-08, EAC TP TC 004 IP65 or IP67 approved,
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
90%
90.5%
20V
36V
4.8A 4A
96W
Compliance to EN55015, EN61000-3-2 Class C ( 50% load, 60% only for 15V model) ; EN61000-3-3, FCC Part 15 Subpart B,≧≧ EAC TP TC 020@ load @ load
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level surge immunity Line-Earth 4KV, Line-Line 2KV , EAC TP TC 020()
EMC IMMUNITY
EMC EMISSION
COLD START 25A(t =900 s measured at 50% I ) at 480VAC;
width peak Per NEMA 410
μ
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 480VAC
CONSTANT CURRENT REGION
Note.4
9~15V 10~20V 12~24V 15~30V 18~36V 21~42V 24~48V 27~54V
THD< 20%(@ load 50%/230VAC, 277VAC, 347VAC [@ load 60% only for 15V model]; @ load 75%/480VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION section)(THD)
File Name:HVG-100-SPEC 2018-05-29
Adjustable for A/AB-Type only (via the built-in potentiometer)
Adjustable for A/AB-Type only (via the built-in potentiometer)
SETUP, RISE TIME Note.6
30ms/347VAC, 480VAC
500ms, 80ms /230VAC, 347VAC, 480VAC
180 ~ 528VAC 254VDC ~ 747VDC
(Please refer to "STATIC CHARACTERISTIC" section)
PF 0.98/230VAC, PF 0.98/277VAC, PF 0.97/347VAC, PF 0.93/480VAC @full load≧≧≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
Tcase=-40 ~ +90 (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
MAX. CASE TEMP.
Tcase=+90
1. All parameters NOT specially mentioned are measured at 347VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.
Please refer to "DRIVING METHODS OF LED MODULE".
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7.
The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
Block Diagram
100W Constant Voltage + Constant Current LED Driver
HVG-100 series
File Name:HVG-100-SPEC 2018-05-29
DRIVING METHODS OF LED MODULE
Typical output current normalized by rated current (%)
This series is able to work in either Constant Current mode (a direct drive way) or
Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
Fosc : 80KHz
DIM+
(B Type)
DIM-
DETECTION
PWM & PFC
CIRCUIT
O.L.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
PFC
CONTROL
O.T.P.
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
Vo(%)
100
50 100
Io (%)
Constant
Voltage area
Constant
Current region
(A)
(B)

HVG-100-20B

Mfr. #:
Manufacturer:
MEAN WELL
Description:
LED Power Supplies 96W 20V 4.8A OCP adj w out cable
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union