cui.com
CUI Inc │ SERIES: VQE50W │ DESCRIPTION: DC-DC CONVERTER date 03/18/2013 │ page 2 of 4
INPUT
parameter conditions/description min typ max units
operating input voltage
24 V input
48 V input
9
18
24
48
36
75
Vdc
Vdc
surge voltage 100 ms max.
24 V input
48 V input
500
100
Vdc
Vdc
under voltage lockout
power up
power down
24 V input
48 V input
24 V input
48 V input
8.8
17
8
16
Vdc
Vdc
Vdc
Vdc
positive logic remote on/off
1
lter PI type
Notes: 1. logic compatibility, open collector ref to -input
Module ON, 3.5 ~ 75 Vdc or open circuit
Module OFF, <1.2 Vdc
2. negative logic remote on/off available
Module ON, <1.2 Vdc current limit, 110~165% nominal output
Module OFF, 3.5 ~ 75 Vdc or open circuit
OUTPUT
parameter conditions/description min typ max units
line regulation measured from high line to low line ±0.2 %
load regulation measured from full load to zero load ±0.2 %
voltage accuracy ±1.5 %
transient response 25% step load change 500 µs
external trim adj. range ±10 %
switching frequency 100% load, input voltage range 300 kHz
temperature coefcient ±0.03 %/°C
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection %Vo 115 140 %
short circuit protection continuous
current limit % nominal output current 110 165 %
thermal shutdown case temp. 110 °C
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output
input to case
output to case
1,500
1,500
1,500
Vdc
Vdc
Vdc
isolation resistance 10 MΩ
isolation capacitance 1,000 pF
safety approvals UL 60950-1, CE
RoHS compliant yes
MTBF MIL-STD-217F, GB, 25°C, full load TBD hours
ENVIRONMENTAL
parameter conditions/description min typ max units
case operating temperature -40 105 °C
storage temperature -55 125 °C
humidity non-condensing 95 %
For more information, please visit the product page.