TLP3041(S),TLP3042(S),TLP3043(S)
2010-10-01
2
Absolute Maximum Ratings
(Ta = 25
°
C)
CHARACTERISTIC SYMBOL RATING UNIT
Forward Current I
F
50 mA
Forward Current Derating
(Ta ≥ 53°C)
ΔI
F
/ °C −0.7 mA / °C
Peak Forward Current
(100
μ
s pulse, 100pps)
I
FP
1 A
Power Dissipation P
D
100 mW
Power Dissipation Derating
(Ta ≥ 25°C)
ΔP
D
/ °C −1.0 mW / °C
Reverse Voltage V
R
5 V
LED
Junction Temperature T
j
125 °C
Off-State Output Terminal Voltage V
DRM
400 V
On-Stage RMS
Ta = 25°C 100
Current
Ta = 70°C
I
T(RMS)
50
mA
On-State Current Derating
(Ta ≥ 25°C)
ΔI
T
/ °C −1.1 mA / °C
Peak On-Stage Current
(100
μ
s pulse, 120pps)
I
TP
2 A
Peak Nonrepetitive Surge
Current (P
W
= 10ms)
I
TSM
1.2 A
Power Dissipation P
D
300 mW
Power Dissipation Derating
(Ta ≥ 25°C)
ΔP
D
/ °C −4.0 mW / °C
DETECTOR
Junction Temperature T
j
115 °C
Storage Temperature Range T
stg
−55 to 150 °C
Operating Temperature Range T
opr
−40 to 100 °C
Lead Soldering Temperature (10s) T
sol
260 °C
Total Package Power Dissipation P
T
330 mW
Total Package Power Dissipation
Derating (Ta ≥ 25°C)
ΔP
T
/ °C −4.4 mW / °C
Isolation Voltage
(AC, 1 min., R.H. ≤ 60%) (Note 1)
BV
S
5000 Vrms
Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even
if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum
ratings.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
Note 1: Device considered a two terminal device: Pins 1, 2 and 3 shorted together and pins 4 and 6 shorted
together.
Recommended Operating Conditions
CHARACTERISTIC SYMBOL MIN TYP. MAX UNIT
Supply Voltage V
AC
⎯ ⎯ 120 Vac
Forward Current I
F
* 15 20 25 mA
Peak On-Stage Current I
TP
⎯ ⎯ 1 A
Operating Temperature T
opr
−25 ⎯ 85 °C
Note: Recommended operating conditions are given as a design guideline to obtain expected performance of the
device. Additionally, each item is an independent guideline respectively. In developing designs using this
product, please confirm specified characteristics shown in this document.
* : In the case of TLP3042