3 07/12
Please read Cautions and warnings and
Important notes at the end of this document.
Dimensional drawing (dimensions in mm)
Technical data and measuring conditions
Rated voltage V
R
500 V AC (50/60 Hz) / 600 V DC
During operation between winding and metal parts
(VDE 0565-2).
Test voltage V
test
2800 V AC, 2 s (winding/core)
2800 V AC, 2 s (winding/case)
Rated temperature T
R
+60 C
Rated current I
R
Referred to 50 Hz and rated temperature
Permissible operating current at 400 Hz 0.6 · I
R
Rated inductance L
R
Measured with Agilent 4284A at 0.1 mA, +20 C
Measuring frequency: L
R
1 mH = 100 kHz
L
R
> 1 mH = 10 kHz
Inductance tolerance 20% at +20 C
DC resistance R
typ
Measured at +20 C, typical values
Storage conditions (packaged) –25 °C … +40 °C, 75% RH
Climatic category 40/125/56 (to IEC 60068-1)
Weight Approx. 170 … 230 g
IND0461-C
68±0.2
78 max.
17±0.2
28 max.
ø3.6
ø6.5
4
32±0.8
36.5
0.5
_
+1
M4
Tolerances to ISO 2768-C
unless otherwise noted.
Dimensions in mm
B82504WPower line chokes
I core chokes