CMI-4537-SN69

date
page
PART NUMBER: DESCRIPTION:
06/2012
1 of 4
ELECTRET CONDENSER
MICROPHONE
CMI-4537-SN69
20050 SW 112
th
Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.cui.com
SPECIFICATIONS
parameter conditions/description min nom max units
directivity unidirectional
sensitivity f= 1 KHz, 1Pa 0 dB= 1 V/Pa -40 -37 -34 dB
operating voltage 1.5 9 V dc
output impedance f= 1 KHz, 1Pa 1.26 1.8 2.34 KΩ
sensitivity reduction f= 1 KHz, 1Pa Vs=1.5 V dc to 1.1 V dc -3 dBA
frequency 100 12,000 Hz
current consumption Vs=1.5 V dc RL=2.0 KΩ 0.4 mA
signal to noise ration f= 1 KHz, 1 Pa A weighted 69 dBA
operating temperature -20 70 °C
storage temperature -20 70 °C
dimenstions ø9.7 x H4.5 mm
weight 0.8 g
material Aluminum
terminal terminal type
RoHS yes
4.5
9.7
TERMINAL 2
TERMINAL 1
1.0
(6 PLCS)
APPEARANCE DRAWING
For more information, please visit the product page.
date
page
PART NUMBER: DESCRIPTION:
06/2012
2 of 4
ELECTRET CONDENSER
MICROPHONE
CMI-4537-SN69
20050 SW 112
th
Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.cui.com
FREQUENCY RESPONSE CURVE
MEASUREMENT CIRCUIT
For more information, please visit the product page.
date
page
PART NUMBER: DESCRIPTION:
06/2012
3 of 4
ELECTRET CONDENSER
MICROPHONE
CMI-4537-SN69
20050 SW 112
th
Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.cui.com
MECHANICAL CHARACTERISTICS
item test condition evaluation standard
soldering heat resistance Soldering iron with 270 ±5°C should be applied on the terminal for
2 ±0.5 seconds.
No interference in operation.
PCB wire pull strength The force of 4.9 N is applied for 30 sec. to double lead wire. No damage or cutting off.
vibration test The microphone should be measured after a vibration amplitude
of 1.5 mm with 10 ~ 55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
The sensitivity should be within
±3dB compared with the initial
measurement.
drop test The microphone without packaging is subjected to 3 drops on
each axis from the height of 1 m onto a 10 mm thick wooden
board.
ENVIRONMENT TEST
item test condition evaluation standard
high temperature test After being placed in a chamber at +70°C for 72 hours.
The microphone will be measured
after being placed at +25°C for 6
hours. The value of the oscillation
frequency should be ±10% compared
to the initial measurements. The SPL
should be within ±3dB compared to
the initial measurements.
low temperature test After being placed in a chamber at -20°C for 72 hours.
humidity test After being placed in a chamber at +40°C and 90 ±5% RH for
240 hours.
temperature cycle test The part will be subjected to 10 cycles. One cycle will consist of:
TEST CONDITIONS
standard test conditions a) Temperature: +5 ~ +35°C b) Humidity: 45 ~ 85% c) Pressure: 860 ~ 1060 mbar
judgement test conditions a) Temperature: +25 ±2°C b) Humidity: 60 ~ 70% c) Pressure: 860 ~ 1060 mbar
+70к
+25к +25к
-20к
1hr 0.5hr 1hr 0.5hr 1hr 0.5hr 1hr
5.5 hrs