E4B-RS70E4 2M

E4B
E4B
11
Dimensions
Unit: mm (inch)
J E4B-TS50
E4B-T1
E4B-LS20
E4B-LS70
E4B-RS70
Tw o , M 4 x 4 5
4.5 dia.
(See Note.)
Note: Vi nyl-insulated round cable
with three conductors, 6 dia.;
standard l ength: 2 m
62
49.5
35
(1.38)
25
32
10
35
79 (3.11)
20
8
5
R2.5
25
66
50 (1.97) 8
11.5
71.5
61
(2.40)
57
17.5
44.5
11.5
38
Precautions
J SENSOR MOUNTING ANGLE
If the E 4B is in level control or distance control of sensing
objects, the stability of signal detection will depend on the
sensing surface condition of the objects. Considering the repose
angle of the objects, mount the E4B so that the ultrasonic beam
and the sensing surface of each object meet at right angles to
each other.
J SURROUNDING OBJECTS
Make sure that the Sensor is free from surroundi ng objects that
reflect the ul trasonic beam diffusi on, otherw ise the Sensor may
malfunction. In particular, pay the utmost attention so that no side
lobe of the ultrasonic beam will be reflected by such objects.
J MOUNTING
Securely mount the E4B by using the nuts provided with the E4B
or the mounting holes of the E4B. Refer to Di mensions for
details.
Do not strike the Sensor with hammer or other object, otherw ise
the E4B will no longer be water-resistant.
If the E 4B is not mounted securely, the E4B may be damaged by
vibration or may not detect target objects accurately due to a
possible change i n the mounting posi tion.
E4BE4B
J ENVIRONMENTAL CONDITIONS
Do not use the E4B at a temperature exceeding the rated range
or outdoors, otherwise the reliability and life of the E4B will
decrease.
The Ultrasonic Reflective Sensor utilizes the air as a beam
transmission media. Do not use the E4B in places with radical
convecti on or extreme l ocal temperature changes. For example,
if there is a hot air curtain that causes turbulence within the
sensing area, the E4B may malfunction.
Turbulence
Air curtain
Emitter
Receiver
The jetting sound of air nozzles includes noise of a wide
frequency range, w hich will affect the operation of the E4B . Do
not use an ai r nozzle near the E4B.
The sensing distance of the E4B will decrease if there is any
water drops on the surface of the emitter or receiver.
The through-beam model may not detect any objects if there is
any object absorbing sound, such as powder and cotton, on the
surface of the emitter or receiver.
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
R
OMRON ON--LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci

E4B-RS70E4 2M

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Proximity Sensors ZONE SENSING NPN 70c m 12/24VDC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union