Supervisory Circuit
2016-01-0003 PT0196-6 01/15/16
1
Features
Highly accurate: 1.5% (25°C)
Detect voltage range: 1.8 to 5V in 100mV increments
Operating voltage range: 1.0V ~ 5.5V
Operating temperature range: -40°C to + 85°C
Detect voltage temperature characteristics: 2.5%
TYP
Output configuration: Bi-dir
Four reset timeout period available:
typical 1.6ms for PT7M6314USxxD1;
typical 26ms for PT7M6314USxxD2;
typical 200ms for PT7M6314USxxD3;
typical 1570ms for PT7M6314USxxD4;
General Description
The series are designed to monitor power supplies in µP
and digital systems. It provides excellent circuit
reliability and low cost by eliminating external
components and adjustments, and a debounced manual
reset input.
This device performs a single function: it asserts a reset
signal whenever the V
CC
supply voltage falls below a
preset threshold or whenever manual reset is asserted.
Reset remains asserted for an internally programmed
interval (reset timeout period) after V
CC
has risen above
the reset threshold or manual reset is de-asserted.
PT7M6314USxx are bidirectional output, allowing it to
be directly connected to µP with bidirectional reset inputs.
The serials come with factory-trimmed reset threshold
voltages in 100mV increments from 2.5V to 5V. Preset
timeout periods of 200ms and 1570ms (typ.) are available.
Pin Configuration
Pin Description
Reset Output and Pushbutton Input: RST is asserted when V
CC
drops below voltage threshold V
TH-
. Active
low. When other devices pull RST low, the device will speed its rising edge once the reset condition release.
Manual Reset: A logic low on MR asserts reset. Reset remains asserted as long as MR is low, and for the
reset timeout period (t
RS
) after the reset conditions are terminated. Connect to V
CC
if not used.
1
2
VCC
RST
GND
3
4
MR
PT7M6315USxxD3F/D4F
SOT143-4