SPECIFICATION CONTROL DRAWING
Page
2 of 2
Revision
H
SCD
ATF+0311
TABLE II. PERFORMANCE DETAILS
PART NUMBER
1/
HEAT RESISTANCE - BEND TESTING
DYNAMIC CUT-THROUGH
(lb) (kg) (minimum)
MANDREL DIAMETER
(inch) (mm) (± 3%)
WEIGHT
(lb) (kg) (± 3%)
INITIAL
AFTER
IMMERSION
ATFC0311-22-* .750 (19.1) .375 (.170) TBD TBD
ATFC0311-20-* .750 (19.1) .375 (.170) 20 (9.07) 20 (9.07)
ATFC0311-18-* .750 (19.1) .375 (.170) TBD TBD
ATFC0311-16-* .750 (19.1) .375 (.170) TBD TBD
ATFC0311-14-* .750 (19.1) .375 (.170) TBD TBD
ATFD0311-16-* 1.00 (25.4) .500 (.227) TBD TBD
ATFD0311-14-* 1.00 (25.4) .500 (.227) TBD TBD
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
VOLTAGE RATING: 600 volts (dc) at sea level
CONCENTRICITY: 70% (minimum)
CROSSLINK PROOF TEST: Per QC/3/117
FLAMMABILITY: 70 seconds (maximum) afterburn
HEAT RESISTANCE: 150 ± 2°C for 1 hour
no cracking, no dielectric breakdown
INSULATION ELONGATION AND TENSILE STRENGTH:
(Pulled at 2 inches (51 mm) per minute)
Elongation, 150% (minimum)
Tensile Strength, 3000 lbf/in
2
(20.7 N/mm
2
) (minimum)
INSULATION FLAWS:
Impulse Dielectric,
ATFC0311, 14 AWG and smaller, 5.0 kV (peak)
ATFD0311-16, 5.0 kV (peak)
ATFD0311-14, 6.0 kV (peak)
INSULATION RESISTANCE:
1000 kohms for 1000 ft. (305 kohms for 1 km) (minimum)
LOW TEMPERATURE-COLD BEND: -55 ± 3°C for 4 hours
SHRINKAGE: 0.050 inch (1.27 mm) (maximum)
STRIP FORCE: 4.5 lbs (2.04 kg) (minimum)
THERMAL STABILITY: Short Term, 200 ± 3°C for 168 hours
Elongation Retention, 80% (minimum)
Tensile Strength Retention, 80% (minimum)
TRANSMISSION FLUID RESISTANCE: Dexron VI, 150 ± 2°C for 720 hours
Diameter Swell, 5% (maximum)
Mandrel Wrap, 1x diameter mandrel, no dielectric breakdown
Dynamic Cut-Through, see Table II
VOLTAGE WITHSTAND (Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
1/ PART NUMBER:
The "+" in the part number in the upper right hand corner of pages 1 and 2
shall be replaced with a letter designator to define conductor stranding
(see part numbers in table).
C = 19 Strands D = 37 Strands
The "*" in the part numbers in Tables I and II shall be replaced by a color
code designator.
Example: AWG 20, 19 strands, dark blue: ATFC0311-20-6D
1/ See footer section on page 1