KD1084AXX, KD1084AXX18 Maximum ratings
Doc ID 8761 Rev 11 5/17
3 Maximum ratings
Note: Absolute maximum ratings are those values beyond which damage to the device may occur.
Functional operation under these condition is not implied.
Table 2. Absolute maximum ratings
Symbol Parameter Value Unit
V
I
DC input voltage 12 V
I
O
Output current Internally limited
P
D
Power dissipation Internally limited
T
STG
Storage temperature range -55 to +150 °C
T
OP
Operating junction temperature range -40 to +125 °C
Table 3. Thermal data
Symbol Parameter DPAK D²PAK Unit
R
thJC
Thermal resistance junction-case 8 3 °C/W
R
thJA
Thermal resistance junction-ambient 100 62.5 °C/W
Obsolete Product(s) - Obsolete Product(s)