GU140X16J-7003
- 6 -
Receiving Buffer Capacity: 12 byte
SBUSY change timing:
SBUSY 1(BUSY) 0(READY)
Condition When there is data in buffer When there is no data in buffer
Data can be stored into receiving buffer. However, it recommends not sending
the data when SBUSY=1.
5.2.3 Synchronous serial interface timing
Receiving Buffer Capacity: 12 byte
SBUSY change timing:
SBUSY 1(BUSY) 0(READY)
Condition When there is data in buffer When there is no data in buffer
Data can be stored into receiving buffer. However, it recommends not sending
the data when SBUSY=1.
5.3 Reset timing
Reset pulse (active low) should be longer than 1mS.
The module sets the SBUSY line upon receipt of Reset signal and clears the line when ready to
receive the data.
Min.
1.5μs
SIN
/Reset
Min.
1ms
SBUSY
Max.
100ms
VALID
SBUSY
SIN
Max.
20μs
Min.
200ns
Min.
200ns
D0 D1 D2 D3 D4 D5 D7
SCK
Min.
0μs
D0
1
0
1
0
D6
Min.
200ns
Min.
200ns
Min.
500ns
GU140X16J-7003
- 7 -
6 Display specification
6.1 Displayable image types
6.1.1 Graphic display
Number of dot: 140 x 16 dots
6.1.2 Character display
Character mode: 5 x 7 dot
Character font type: 5 x 7 dot - Characters, ANK, international font
Character display width: Fixed character format 1 & 2, Proportional character format 1 & 2.
Attribution: Character magnify, Reverse
6.2 Display memory
Size: 512x 16 dots - separated as: Display area (140x16dots)
Hidden area (372x16dots).
Hidden area also can be displayed by using “Display action command group” Refer to
“Display action command group”, Page 18.
By using “User Window” function, All display area can be separated, and each window
separated can be controlled independently.
x
A
ll display memory 512 dots
y
B7
B6
B5
B4
B3
B2
B1
B0
0
1
0 5111 510
16
dots
139
Display area 140 dots Hidden area 372 dots
GU140X16J-7003
- 8 -
6.3 Window
Window function divides display screen as “Window” ,and each divided “Window” can be controlled
and displayed independently. Refer to “Window command group”, Page 22.
There is no independed display memories for each “Window”.
There are 2 types of “Window”, Base-Window and User-Window .
6.3.1 Base-Window
This has the whole display screen and if User-Window is not defined, all display operation is
processed under this Base-Window.
When some User-Window is defined, the display operation to the out of display screen of
User-Window should be processed under Base-Window.
When Base-Window is selected even if some User-Window is defined, all of display operation is
processed under Base-Window. Therefore, the current display pattern of User-Window is
overwritten.
6.3.2 User-Window
User-Window is defined by command, and display operation can be processed on
User-Window selected by “Current Window select” command.
User-Window can be defined up to 4 windows.
Base-Window
ABCDEFG
HIJKLMN
OPQRSTU User-Window
01234567
Base-Window
User-Window 2
User-Window 3
User-Window 1
User-Window 4

GU140X16J-7003