ENVIRONMENTAL
Parameter Condition
Operating Temperature Range
without derating
with derating
-40°C to +94°C
Maximum Case Temperature +105°C
Temperature Coefficient ±0.02%/°C max.
Thermal Impedance
(9)
Natural convection (20LFM)
Natural convection (20LFM) with heatsink
12°C/Watt
10°C/Watt
Operating Humidity non-condensing 5% - 95% RH
Thermal Shock MIL-STD-810F
Vibration MIL-STD-810F
MTBF
MIL-HDBK-217F, Full Load
Bellcoe TR-NWT-000332
(10)
3342 x 10
3
hours
1976 x 10
3
hours
PD-4
REV.: 3/2016 www.recom-power.com
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP10-EW
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
UL General Safety E196683
UL60950-1 1st Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
EMC Compliance Condition Standard / Criterion
EMI Standard
(12)
with external filter EN55022, Class A or B
ESD
Radiated Immunity
Fast Transient
(13)
Surge
(13)
Conducted Immunity
Air ±8kV and Contact ± 6kV
10 V/m
±2kV
±2kV
10 Vr.m.s
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria B
EN61000-4-6, Criteria A
continued on next page
Derating Graph
(11)
Notes:
Note9: Heatsink is optional and P/N 7G-0020C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks
including antivibration fixing clips (add suffix -HC). See application notes for further details.
Note10: BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment).
Note11: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
-40 60
78 94
80
10040
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
-40 60
83
80
94
100
40
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
RP10-2412SEW RP10-2412SEW with Heat-sink