Features
Regulated
Converters
• 4:1 Wide Input Voltage Range
• 1.6kVDC Isolation
• UL Certified
• Efficiency up to 84%
• Fixed Operating Frequency
• Six-Sided Continuous Shield
PD-1
REV.: 3/2016www.recom-power.com
DC/DC Converter
3
Y
E
A
R
w
a
r
r
a
n
t
y
3
Description
The RP10-EW series wide input range DC/DC converters are certified to UL 60950-1 and cUL 60950-1.
This makes them ideal for all telecom and industrial applications where approved safety standards are
required. The industry standard 2” x 1” package meets military standards for thermal shock and vibra-
tion tolerance and is available with an optional remote on/off control pin.
E196683
10 Watt
2“ x 1“
Single & Dual
Output
RP10-EW
Selection Guide
Part Number Input Output Output Input
(1)
Efficiency
(1)
Max. Capacitive
Voltage Range Voltage Current Current typ. Load
(2)
[VDC] [VDC] [mA] [mA] [%] [µF]
RP10-243.3SEW
3,4)
9-36 3.3 2500 441 78 6800
RP10-2405SEW
(3,4)
9-36 5 2000 521 80 4700
RP10-2412SEW
(3,4)
9-36 12 830 494 84 690
RP10-2415SEW
(3,4)
9-36 15 670 517 81 470
RP10-483.3SEW
(3,4)
18-75 3.3 2500 226 76 6800
RP10-4805SEW
(3,4)
18-75 5 2000 322 81 4700
RP10-4812SEW
(3,4)
18-75 12 830 247 84 690
RP10-4815SEW
(3,4)
18-75 15 670 249 84 470
RP10-2405DEW
(3,4)
9-36 ±5 ±1000 508 82 ±680
RP10-2412DEW
(3,4)
9-36 ±12 ±416 520 80 ±330
RP10-2415DEW
(3,4)
9-36 ±15 ±333 520 80 ±110
RP10-4805DEW
(3,4)
18-75 ±5 ±1000 254 82 ±680
RP10-4812DEW
(3,4)
18-75 ±12 ±416 267 78 ±330
RP10-4815DEW
(3,4)
18-75 ±15 ±333 257 81 ±110
UL60950-1 Certified
Input Voltage
Output Voltage
Single or Dual
RP10-__ __ _EW/_ _
Ordering Examples:
RP10-1205SEW/P = 12V Input, 5V Output, Positive Logic CTRL pin fitted
RP10-4805DEW-HC = 48V Input, 5V Output, No CTRL pin, Heatsink fitted
Model Numbering
Package
(4)
Control Logic
(3)
Notes:
Note3: add suffix “P” for CTRL function with Positive Logic (1=ON, 0=OFF)
add suffix “N” for CTRL function with Negative Logic (0=ON, 1=OFF)
Note4: add suffix -HC for premounted Heat-sink and clips
Notes:
Note1: Maximum value at nominal input voltage and full load.
Note2: Test by minimum Vin and constant resistor load.