E3B2 E3B2
5
Engineering Data
■ EXCESS GAIN RATIO
100
10
1
0
5
(16.40)
10
(32.81)
15
(49.21)
Detecting distance in meters (feet)
with E39-R2 reflector
Excess gain ratio
E3B2-R5M4■-US
30
20
10
1
0
5
(16.40)
10
(32.81)
13
(42.65)
Detecting distance in meters (feet)
Excess gain ratio
100
10
1
0
1
(3.28)
2
(6.56)
3
(9.84)
Detecting distance in meters (feet)
with 30 x 30 cm (11.8 x 11.8 in)
90% reflectance mat paper
Excess gain ratio
E3B2-D2M4
-US-N-
1
(3.28)
2
3
(9.84)
Detecting distance in meters (feet)
with 30 x 30 cm (11.8 x 11.8 in)
90% reflectance white mat paper
Excess gain ratio
0
4
6
8
1
3
5
10
30
5
(16.40)
7
(22.97)
9
(29.53)
E3B2-D2M4
US-
E3B2-R7M4
-USE3B2-R5M4
-US-
■ OPERATING RANGE
E3B2-R5M4
-US-
E3B2-D2M4
-US-N-
2
Reflector setting distance X in meters
Parallel offset distance Y in cm
4
6
8
13
5
10
30
7
9
10
30
10
50
40
20
50
40
20
0
Y
X
80
(3.15)
40
(1.57)
Detecting distance in meters (feet)
with 30 x 30 cm (11.8 x 11.8 in)
90% reflectance white mat paper
0
0
Parallel offset distance Y in cm
0
-40
(-1.57)
-80
(-3.15)
0.30
(1)
0.60
(2)
0.91
(3)
1.21
(4)
1.51
(5)
1.81
(6)
2.11
(7)
2.42
(8)
2.72
(9)
3.02
(10)
3.32
(11)
3.62
(12)
3.93
(13)