FTB-150-324-H

FTB series(80,100,150A)
Three phase input type(2-stage filter)
FTB -80 -663 -O
Ordering information
1 Model Name
2 Rated Current
3 Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code
Leakage Current
(Input 250/500V 60Hz)
(355only 250/400V 60Hz)
Line to ground
capacitor CY1
(nominal value)
Line to ground
capacitor CY2
(nominal value)
203 1.0mA/2.0mA max 10,000pF 10,000pF
663 2.5mA/5.0mA max 33,000pF 33,000pF
324 12mA/24mA max 220,000pF 100,000pF
355
*
1 330mA/515mA max 220,000pF 3,300,000pF
*
When the line to ground capacitor code is different, the
attenuation characteristic is different.
*
1
“355” is applied only to “L type.
4 Option
H:Ultra high attenuation type
“355” is not applied
S:Hexagon socket head cap screw
(Standard type is Hexagon head screw)
L:Ultra high attenuation type for EU
1 2 3 4
Features of FTB series
Circuit Diagram Derating Curve
Book type (Space-saving type)
- 2-stage filter High-attenuation (150kHz - 1MHz)
-
Selectable leakage current value,Ultra high attenuation type
"-355-L" for EU (Wye type with neutral earth system)
R
Specifications
No. Items FTB-80-663 FTB-100-663 FTB-150-663
1 Rated Voltage[V] AC Three Phase 500 (voltage range:528 max) 50/60Hz
*2
2 Rated Current[A] 80 100 150
3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity
*3
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100M
W
min at room temperature and humidity *4
5 Leakage current 250/500V 60Hz 2.5mA/5.0mA max
6 DC resistance 10m
W
max 8m
W
max 6m
W
max
7 Safety agency approval temperatures -25 to +85
C
(Refer to Derating Curve)
8 Operating temperature -40 to +85
C
(Refer to Derating Curve)
9 Operating humidity 20 to 95%RH (Non condensing)
10 Storage temperature/humidity -40 to +85
C
/20 to 95%RH (Non condensing)
11 Vibration 10 to 55Hz, 19.6m/s
2
(2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact 196.1m/s
2
(20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC
14 Case size (without projection)
100
X
170
X
350 mm (W
X
H
X
D)
100
X
210
X
400 mm (W
X
H
X
D)
[3.94
X
6.69
X
13.78 inches] [3.94
X
8.27
X
15.75 inches]
15 Weight 5.3kg max 7.8kg max
*2 Only capacitor code “355”, Three Phase D-connection : 400 (440 max), Wye-connection : 500 (528 max)
*3 Only capacitor code “324”,”355” 2,800 DC (Cutoff Current = 10mA), 1minute at room temperature and humidity.
*4 Only capacitor code “355”, Isolation resistance specification is deleted.
70 80 90-20 40 50 60
20
0
-40 -30
100
80
60
40
Ambient Temperature [C]
Load Factor [%]
Case
Case
: Mounting Plate
CY1, CY2 : Line to ground capacitor
: Mounting Plate
CY1, CY2 : Line to ground capacitor
L
INE
1
2
3
LOA
D
4
5
6
CY1
CY1
CY2
CY2
L
INE
1
2
3
LOA
D
4
5
6
CY1
CY1
CY2
CY2
*Keep free ventilation holes for cooling.
(1) Line to ground capacitor code : 203, 663, 324
(2) FTB-O O-355-L
FTB-1
FTB series (80,100,150A)
External view
2-
f
6.5
170
6.5
6.5
143
143
80
±
0.5
335
±
0.5
20
20
350
28
100
26
309
head cap screws)
Hexagon socket
The air hole for heat radiation is not on the opposite side side.
Mounting Plate
Input Terminal
Name Plate
3-M8 (Option-S:
head cap screws)
Hexagon socket
Output Terminal
3-M8 (Option-S:
head cap screws)
Hexagon socket
M6 (Option-S:
head cap screws)
Hexagon socket
M6 (Option-S:
Mounting Hole
Mounting Hole
Protection Earth
Protection Earth
Terminal Cover
Terminal Cover
Tolerance : ±1 [±0.04]
Weight : 5.3kg max
Mounting Plate : Aluminum=2.0 [0.08]
Dimensions in mm, [ ]=inches
Terminal block screw tightening torque
M89.2Nm(93.9kgfcm)max
Protection Earth (PE) screw tightening torque
M65.8Nm(59.2kgfcm)max
Can not be mounted upside-down
(mounted the top surface)
Keep free ventilation holes for cooling
[13.78]
[12.17]
[13.19]
[3.94]
[0.26]
[0.26]
[0.26]
[3.15]
[5.63]
[1.1]
[6.69]
[5.63]
[1.02]
[0.79]
[0.79]
2-f6.5
210
359
6.5
6.5
183
183
100
400
26
28
20
20
385
±0.5
80
±0.5
head cap screws)
Hexagon socket
The air hole for heat radiation is not on the opposite side side.
Mounting Plate
Input Terminal
Name Plate
3-M8 (Option-S:
head cap screws)
Hexagon socket
Output Terminal
3-M8 (Option-S:
head cap screws)
Hexagon socket
M6 (Option-S:
head cap screws)
Hexagon socket
M6 (Option-S:
Mounting Hole
Mounting Hole
Protection Earth
Protection Earth
Terminal Cover
Terminal Cover
Tolerance : ±1 [±0.04]
Weight : 7.8kg max
Mounting Plate : Aluminum=2.0 [0.08]
Dimensions in mm, [ ]=inches
Terminal block screw tightening torque
M89.2Nm(93.9kgfcm)max
Protection Earth (PE) screw tightening torque
M65.8Nm(59.2kgfcm)max
Can not be mounted upside-down
(mounted the top surface)
Keep free ventilation holes for cooling
[15.75]
[14.13]
[15.16]
[3.94]
[0.26]
[0.26]
[0.26]
[3.15]
[7.2]
[1.1]
[8.27]
[7.2]
[1.02]
[0.79]
[0.79]
FTB-80-
OOO
/ FTB-100-
OOO
FTB-150-
OOO
FTB-2

FTB-150-324-H

Mfr. #:
Manufacturer:
Cosel
Description:
AC Power Line Filters Power Line Filters EMI Filte
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union