ADuM3300/ADuM3301 Data Sheet
Rev. D | Page 10 of 20
PACKAGE CHARACTERISTICS
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions
Resistance (Input to Output)
1
I-O
12
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
33 °C/W Thermocouple located at
center of package underside
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
28 °C/W
1
The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM3300/ADuM3301 is approved by the organizations listed in Table 5. See Table 10 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
Recognized under UL 1577
Component Recognition
Program
1
Approved under CSA Component Acceptance Notice #5A Certified according to DIN V VDE V
0884-10 (VDE V 0884-10): 2006-12
2
Single protection,
2500 V rms isolation voltage
Basic insulation per CSA 60950-1-03 and IEC 60950-1,
800 V rms (1131 V peak) maximum working voltage
Reinforced insulation per CSA 60950-1-03 and IEC 60950-1,
400 V rms (566 V peak) maximum working voltage
Reinforced insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL1577, the ADuM3300/ADuM3301 are proof tested by applying an insulation test voltage ≥3000 V rms for 1 second (current leakage detection
limit = 5 µA).
2
In accordance with DIN V VDE V 0884-10, the ADuM3300/ADuM3301 are proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial
discharge detection
limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration
Minimum External Air Gap (Clearance)
Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 8.1 min mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)