File Name:HLG-240H-SPEC 2018-05-29
240W Constant Voltage + Constant Current LED Driver
HLG-240H series
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
Adjustable for A/AB/C-Type only (via built-in potentiometer)
1000ms,80ms/115VAC 500ms,80ms/230VAC
15ms / 115VAC, 230VAC
47 ~ 63Hz
4A / 115VAC 2A / 230VAC
1.2A / 277VAC
<0.75mA / 277VAC
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN55032 (CISPR32) Class B, EN61000-3-2 Class C ( ) ; EN61000-3-3
@ load 50%≧ ,GB17743
and GB17625.1
,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level ()surge immunity Line-Earth 4KV, Line-Line 2KV
Tcase= -40 ~ +90℃
(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
℃
±℃ ℃
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
207.9K hrs min. MIL-HDBK-217F (25 )
℃
244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H C-Type)
1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B) -Type
1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240 C )
Shut down and latch off o/p voltage, re-power on to recover
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
90%
90%
91.5%
92.5%
92.5%
92.5%
93%92.5% 93.5%
±2.5%
8 ~ 16A
±2.0%
7.5 ~ 15A
±1.0%
6 ~ 12A
±1.0%
5 ~ 10A
±1.0%
4 ~ 8A
±1.0%
3.3 ~ 6.7A
±1.0%
2.5 ~ 5A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
2.23 ~ 4.45A
±0.5%
±0.5%
±1.0%
2.86 ~ 5.72A
±0.5%
±0.5%
HLG-240H-12
HLG-240H-15
HLG-240H-20
HLG-240H-24
HLG-240H-30
HLG-240H-36
HLG-240H-48
12V
6 ~12V
15V
7.5 ~ 15V
20V
10 ~ 20V
24V
12 ~ 24V
30V
15 ~ 30V
36V
18 ~ 36V
48V
24 ~ 48V
16A 15A 12A 10A
8A
6.7A
5A
192W 225W 240W 240W 240W
241.2W
240W
150mVp-p 150mVp-p
14 ~ 16V
150mVp-p
18.6 ~ 21.4V
150mVp-p
22.4 ~ 25.6V
200mVp-p
28 ~ 32V
250mVp-p
33.5 ~ 38.5V
250mVp-p
44.8 ~ 51.2V11.2 ~ 12.8V
HLG-240H-54
54V
27 ~ 54V
4.45A
240.3W
350mVp-p
50 ~ 57V
HLG-240H-42
42V
21 ~ 42V
5.72A
240.24W
250mVp-p
39 ~ 45V
EMC IMMUNITY
EMC EMISSION
13.5 ~ 18V 17.5 ~ 21.5V
23.5 ~ 27.5V
27 ~ 34V
33 ~ 39V
43 ~ 49V 55 ~ 63V
48 ~ 54V 60 ~ 67V
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
CONSTANT CURRENT REGION
Note.4
UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750(type”HL”), CSA C22.2 No. 250.0-08; EN/AS/NZS 61347-1,
EN/AS/NZS 61347-2-13 independent (except for HLG-240H C type); UL60950-1, UL8750, TUV EN60950-1; GB19510.1,
;IP65 or IP67; J61347-1, J61347-2-13 BIS IS15885( for 48V only), EAC TP TC 004 approved
,GB19510.14
COLD START 75A(t =570 s measured at 50% I ) at 230VAC;
width peak Per NEMA 410
μ
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
Adjustable for A/AB/C-Type only (via built-in potentiometer)
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
PF 0.98/115VAC, PF 0.95/230VAC @ full load≧≧
(Please refer to " " section)POWER FACTOR (PF) CHARACTERISTIC
THD< 20% (@ load 50% / 115VAC,230VAC; @ load 75% / 277VAC)≧≧
(Please refer to TOTAL HARMONIC DISTORTION (THD) section)""
MAX. CASE TEMP.
Tcase= +90℃
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. driver
The is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanently
driver
connected to the mains.
9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less.℃
1 . Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.0
11. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
EAC TP TC 020