cui.com
CUI Inc │ SERIES: VASD1-DIP │ DESCRIPTION: DC-DC CONVERTER date 01/13/2014 │ page 2 of 5
INPUT
parameter conditions/description min typ max units
operating input voltage
5 V model
12 V model
15 V model
24 V model
4.5
10.8
13.5
21.6
5
12
15
24
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
OUTPUT
parameter conditions/description min typ max units
line regulation for Vin change of 1% 1.2 %
load regulation
measured from 10% load to full load
5 V model
9 V model
12 V model
15 V model
10.5
8.3
6.8
6.3
15
15
15
15
%
%
%
%
voltage accuracy see derating curves
switching frequency 100% load, input voltage range 100 kHz
temperature coefcient ±0.03 %/°C
PROTECTIONS
parameter conditions/description min typ max units
short circuit protection 1 s
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage for 1 minute at 1 mA max. 1,000 Vdc
isolation resistance at 500 Vdc 1,000 MΩ
safety approvals UL 60950-1 (E222736)
MTBF 3,500,000 hours
burn-in full load at 85°C, 4 hours at no load and 4 hours at full load
RoHS compliant yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature -40 85 °C
storage temperature -55 125 °C
storage humidity non-condensing 95 %
temperature rise at full load 15 25 °C
lead temperature 1.5 mm from case for 10 seconds 300 °C
For more information, please visit the product page.