International Symbols
~
_
!
---
~
a
CAUTION: RISK OF ELECTRICAL SHOCK
AC (ALTERNATION CURRENT)
DC (DIRECT CURRENT)
REFER TO INSTRUCTION MANUAL
GROUND
DOUBLE INSULATION
EITHER DC OR AC
FUSE
Controls and Functions
Push Buttons
Activates back light for LCD (automatically
turns off after approx. 70 sec.)
REC Activates the Min/Max/Ave mode
COMP Activates the Compare mode
REL% Activates the REL% mode
Range Activates manual ranging
EDIT Activates the EDIT mode for Compare and
Relative% functions
HOLD Activates two-hold data-hold mode
Activates special dual functions on LCD.
(Min/MAx time references)
ON/OFF Turns DMM on and off
Data-H Activates the data hold function
Rotary Switch
V Selects the DCV function. Select the best
range for the voltage to be measured
V Selects the ACV function. Select the best
range for the voltage to be measured
A Selects the DCA function. Select the best
range for the current to be measured
A Selects the ACA function. Select the best
range for current to be measured
Selects resistance, diode, or continuity
function
OFF Turns the instrument off
mV Selects the DC mV function
V Selects the DCV function
VHz Selects the ACV function (Push the yellow
button to display frequency of measured
voltage on lower display
Rotary Switch cont’d
Selects the diode test function
Ω Selects resistance function. (Push the
yellow button to activate continuity buzzer)
mA Selects the DC mA function
A Selects the DCA function (10A max.)
A Selects the ACA function (10A max.)
mA Selects the AC mA function
Selects the Capacitance function
Hz Selects the Frequency function
Input Jacks
A Red test lead connection for current
measurements on the 2 and 10 ACA and
DCA functions
mAµA Red test lead connection for current
measurement on the mA and A DCA
and ACA functions
COM Black test lead connection for all
functions
V Red test lead connection for all OHM,
DCV, and ACV functions
---
~
---
~
---
---
~
---
---
~
~
Controls / Functions / International Symbols
FAQ
1. Is there a way to measure
higher current with a TPI
DMM?
TPI DMMs (except the 120 and 126)
have the capacity to read up to 10A
AC/DC. Optional adapters are
available for all models to increase
the current range. Our shunt
adapters are available to increase
the range up to 1,000A AC/DC.
2. What other adapters are
available for TPI DMMs?
Various adapters including carbon
monoxide (A771), pressure
(A620/630), and clamp-on low
current (A254) are available. Contact
TPI for additional information.
3. Which of the TPI DMMs
will measure temperature?
All TPI DMMs can measure
temperature by using the
optional A301 K-Type
thermocouple temperature adapter.
4. Which TPI DMMs can
measure DC millivolts?
All TPI DMMs measure millivolts.
Models are available with 1 or 0.1
millivolt resolution.
5. Which TPI DMMs can
measure DC microamps?
The TPI 126, 133, 135, 153, 163, 183,
190, 194, 196, and 440 all have this
capability.
6. Which TPI DMMs will
measure capacitance?
The TPI 135, 183, 190, 192, 194, and
440 all have this capability.
7. What is continuity?
Continuity refers to a test performed
on wires and circuits to see if a
break(open) exhists. If the wire or
circuit is continuous, the resistance
reading will be at or near zero.
The continuity range on a meter
provides audible indication of a
continuous circuit, allowing quicker
tests without having to take your
eyes off the circuit or wire under
test.
www.tpi-thevalueleader.com
To learn about the entire
line of TPI products visit:
L TAW DMM -1005
Copyright © 2005 Test Products International, Inc.
Test Products
International, Inc.
Headquarters:
9615 SW Allen Blvd.
Beaverton, OR 97005
USA
503-520-9197
Fax: 503-520-1225
email:
info@tpi-thevalueleader.com
Test Products
International, Ltd.
342 Bronte St. South
Unit 9
Milton, Ontario L9T
5B7
Canada
905-693-8558
Fax: 905-693-0888
email:
info@tpicanada.com
Test Products
International UK Ltd.
Longley House, East Park
Crawley, West Sussex
RH10 6AP England
Tel: +44 (0)1293 561212
Fax: +44 (0)1293813465
contactus@tpieurope.com
Distributed By:
TPI offers a
complete line
of…
CO, Combustibles &
Combustion (CEA)
Refrigerant Leak
Detectors
Digital Manometers
Temperature Contact
& IR Instruments
IAQ: Air Flow /
Humidity
Handheld
Oscilloscopes
Digital Multimeters
& Clamp-on Meters
Accessories & Kits
DMM
1. Determine the maximum over voltage installation category (CAT I ~ CAT IV) the multimeter will be used
in and narrow your choice to those meters meeting the requirement. The Category rating for each meter
is listed on page 2 in the specifications table.
2. Narrow your choice by selecting meters with the features required for your intended applications. For
example, if your applications require a CAT III meter with true RMS, frequency, and RS232 output
capabilities, the TPI 183 or TPI190 would be good choices. See applications listed below.
3. Finally, select a meter with enough range, accuracy, and resolution for the tests you will perform. For
example: the TPI 183 and the TPI 190 meet your application needs, but you require precision
high-resolution measurements. Then the 50,000 count TPI 190 would be the better choice.
DMM Selection Guide
120
126
133
135
153
163
183
190 ~ 196
440
Application Market Function 100 120 122 126 133 135 153 163 183 190 192 194 196 440
HVACR Electrical Electronic Industrial
Thermocouples in furnaces and gas appliances • DCmV
Heat anticipator current in thermostats • ACA
Line voltages • • • • ACV
Control voltages • • • • ACV/DCV
Flame safety control current • DCuA
Heating element resistance • Ohms
Compressor winding resistance • Ohms
Contactor and relay coil resistance • • • Ohms
Motor run and start capacitors • • CAP
Use bar graph to indicate rapid fluctuations • • • • ALL
Continuity of wiring • • • • Ohms
Measure frequency on control and line voltage • • • • Hz
Record minimum and maximum of measurements
• • • • REC
Measure temperature
* • • • • DCV * *
Measure True RMS of distorted or non-linear signals
• • • • ACV/ACA
Measure line current up to 10 amps • • • ACA
Test continuity of circuit breakers and fuses • • • Ohms
Measure voltage of direct drive DC motors • • DCV
Measure power supply voltage • ACV/DCV
Measure power supply current • ACA/DCA
High resolution, high accuracy • • • ALL
High resolution, high accuracy • ALL
Category IV tests • • • ACV/DCV
Process loop calibration • mA Out
Power Quality • • • ACV/ACA
Audio • ACV/ACA
Video • ACV
Logic Tests • LOGIC
Waveform Display • • •AC+DCV+A
*Requires either the A301single input or A312 dual input temperature adapters
* * * * * * * * * *
APPLICATIONS
The
Value
Leader
™
See page 3 inside for
ranges, specifications,
and features.
Palm Size
100, 120, 122, 126
Full Size
133, 135, 153, 163,
183, 190, 192, 194,
196
T
rue Rms
183, 190, 192, 194,
440
50,000 Count High
Resolution
190, 192, 194, 196
W
ave Form Display
440
Process Loop
Calibration
196
T
rue RMS Plus
Waveform
440
122
100