153

International Symbols
~
_
!
---
~
a
CAUTION: RISK OF ELECTRICAL SHOCK
AC (ALTERNATION CURRENT)
DC (DIRECT CURRENT)
REFER TO INSTRUCTION MANUAL
GROUND
DOUBLE INSULATION
EITHER DC OR AC
FUSE
Controls and Functions
Push Buttons
Activates back light for LCD (automatically
turns off after approx. 70 sec.)
REC Activates the Min/Max/Ave mode
COMP Activates the Compare mode
REL% Activates the REL% mode
Range Activates manual ranging
EDIT Activates the EDIT mode for Compare and
Relative% functions
HOLD Activates two-hold data-hold mode
Activates special dual functions on LCD.
(Min/MAx time references)
ON/OFF Turns DMM on and off
Data-H Activates the data hold function
Rotary Switch
V Selects the DCV function. Select the best
range for the voltage to be measured
V Selects the ACV function. Select the best
range for the voltage to be measured
A Selects the DCA function. Select the best
range for the current to be measured
A Selects the ACA function. Select the best
range for current to be measured
Selects resistance, diode, or continuity
function
OFF Turns the instrument off
mV Selects the DC mV function
V Selects the DCV function
VHz Selects the ACV function (Push the yellow
button to display frequency of measured
voltage on lower display
Rotary Switch cont’d
Selects the diode test function
Selects resistance function. (Push the
yellow button to activate continuity buzzer)
mA Selects the DC mA function
A Selects the DCA function (10A max.)
A Selects the ACA function (10A max.)
mA Selects the AC mA function
Selects the Capacitance function
Hz Selects the Frequency function
Input Jacks
A Red test lead connection for current
measurements on the 2 and 10 ACA and
DCA functions
mAµA Red test lead connection for current
measurement on the mA and A DCA
and ACA functions
COM Black test lead connection for all
functions
V Red test lead connection for all OHM,
DCV, and ACV functions
---
~
---
~
---
---
~
---
---
~
~
Controls / Functions / International Symbols
FAQ
1. Is there a way to measure
higher current with a TPI
DMM?
TPI DMMs (except the 120 and 126)
have the capacity to read up to 10A
AC/DC. Optional adapters are
available for all models to increase
the current range. Our shunt
adapters are available to increase
the range up to 1,000A AC/DC.
2. What other adapters are
available for TPI DMMs?
Various adapters including carbon
monoxide (A771), pressure
(A620/630), and clamp-on low
current (A254) are available. Contact
TPI for additional information.
3. Which of the TPI DMMs
will measure temperature?
All TPI DMMs can measure
temperature by using the
optional A301 K-Type
thermocouple temperature adapter.
4. Which TPI DMMs can
measure DC millivolts?
All TPI DMMs measure millivolts.
Models are available with 1 or 0.1
millivolt resolution.
5. Which TPI DMMs can
measure DC microamps?
The TPI 126, 133, 135, 153, 163, 183,
190, 194, 196, and 440 all have this
capability.
6. Which TPI DMMs will
measure capacitance?
The TPI 135, 183, 190, 192, 194, and
440 all have this capability.
7. What is continuity?
Continuity refers to a test performed
on wires and circuits to see if a
break(open) exhists. If the wire or
circuit is continuous, the resistance
reading will be at or near zero.
The continuity range on a meter
provides audible indication of a
continuous circuit, allowing quicker
tests without having to take your
eyes off the circuit or wire under
test.
www.tpi-thevalueleader.com
To learn about the entire
line of TPI products visit:
L TAW DMM -1005
Copyright © 2005 Test Products International, Inc.
Test Products
International, Inc.
Headquarters:
9615 SW Allen Blvd.
Beaverton, OR 97005
USA
503-520-9197
Fax: 503-520-1225
email:
info@tpi-thevalueleader.com
Test Products
International, Ltd.
342 Bronte St. South
Unit 9
Milton, Ontario L9T
5B7
Canada
905-693-8558
Fax: 905-693-0888
email:
info@tpicanada.com
Test Products
International UK Ltd.
Longley House, East Park
Crawley, West Sussex
RH10 6AP England
Tel: +44 (0)1293 561212
Fax: +44 (0)1293813465
contactus@tpieurope.com
Distributed By:
TPI offers a
complete line
of…
CO, Combustibles &
Combustion (CEA)
Refrigerant Leak
Detectors
Digital Manometers
Temperature Contact
& IR Instruments
IAQ: Air Flow /
Humidity
Handheld
Oscilloscopes
Digital Multimeters
& Clamp-on Meters
Accessories & Kits
DMM
1. Determine the maximum over voltage installation category (CAT I ~ CAT IV) the multimeter will be used
in and narrow your choice to those meters meeting the requirement. The Category rating for each meter
is listed on page 2 in the specifications table.
2. Narrow your choice by selecting meters with the features required for your intended applications. For
example, if your applications require a CAT III meter with true RMS, frequency, and RS232 output
capabilities, the TPI 183 or TPI190 would be good choices. See applications listed below.
3. Finally, select a meter with enough range, accuracy, and resolution for the tests you will perform. For
example: the TPI 183 and the TPI 190 meet your application needs, but you require precision
high-resolution measurements. Then the 50,000 count TPI 190 would be the better choice.
DMM Selection Guide
120
126
133
135
153
163
183
190 ~ 196
440
Application Market Function 100 120 122 126 133 135 153 163 183 190 192 194 196 440
HVACR Electrical Electronic Industrial
Thermocouples in furnaces and gas appliances DCmV
Heat anticipator current in thermostats ACA
Line voltages ACV
Control voltages ACV/DCV
Flame safety control current DCuA
Heating element resistance Ohms
Compressor winding resistance Ohms
Contactor and relay coil resistance Ohms
Motor run and start capacitors CAP
Use bar graph to indicate rapid fluctuations ALL
Continuity of wiring Ohms
Measure frequency on control and line voltage Hz
Record minimum and maximum of measurements
REC
Measure temperature
* DCV * *
Measure True RMS of distorted or non-linear signals
ACV/ACA
Measure line current up to 10 amps ACA
Test continuity of circuit breakers and fuses Ohms
Measure voltage of direct drive DC motors DCV
Measure power supply voltage ACV/DCV
Measure power supply current ACA/DCA
High resolution, high accuracy ALL
High resolution, high accuracy ALL
Category IV tests ACV/DCV
Process loop calibration mA Out
Power Quality ACV/ACA
Audio ACV/ACA
Video ACV
Logic Tests LOGIC
Waveform Display •AC+DCV+A
*Requires either the A301single input or A312 dual input temperature adapters
* * * * * * * * * *
APPLICATIONS
The
Value
Leader
See page 3 inside for
ranges, specifications,
and features.
Palm Size
100, 120, 122, 126
Full Size
133, 135, 153, 163,
183, 190, 192, 194,
196
T
rue Rms
183, 190, 192, 194,
440
50,000 Count High
Resolution
190, 192, 194, 196
W
ave Form Display
440
Process Loop
Calibration
196
T
rue RMS Plus
Waveform
440
122
100
TPI DIGITAL MULTIMETER TERMINOLOGY
>> Agency Approval: Test equipment with the CE or UL mark have
passed through tests and are designed with operators safety in mind.
>> Record Mode: Record and display the minimum and maximum
readings measured. This feature is useful when looking for trends over
a long period of time.
>> Auto Range: Meter automatically selects the appropriate range after
the function has been selected.
>> Backlight: Feature allowing the display to be illuminated for easier
viewing in low light conditions.
>> Basic DC Accuracy: Important specification affecting the overall
accuracy of all functions on a DMM.
>> Resolution: A measurement of how small of a signal a meter can
display. This specification must be taken into account with accuracy to
determine the overall capability of a DMM.
>> True RMS: Allows accurate measurement of non-sinusoidal AC volt-
age and current found in many control and switching power supply
circuits.
>> Analog Bar Graph: Provides the ability to see rapidly changing
signals too fast for the digital display to see.
>> Triple Display Simultaneosly display more than one reading at the
same time. This feature is useful when measuring AC volts beacuse the
frequency can be displayed at the same time without having to switch
ranges
>> Sleep/Auto Off: Automatically powers instrument down after 30
minutes of inactivity to preserve battery life. Meters with sleep mode
will still acquire data during this time
>> Data Hold: Freezes the reading on the display. This feature is useful
when recording readings on paper or when in hard to see locations.
Triple display meters can hold two readings on the display at the same
time.
>> Input Impedance: Total resistance of the meter as measured at the
input terminals. Meters with high impedance, 10Mor more, cause
negligible loading of the circuit under test. This is important because
circuit loading can adversely influence the displayed reading and can
cause damage to the circuit under test.
>> Record Mode: Record and display the minimum and maximum
readings measured. This feature is useful when looking for trends over
a long period of time.
>> Relative Mode: Displays measured value as a percentage of the
stored value. This feature is useful for component checking.
>> Compare Mode: Compares measured value with stored value. This
feature is useful when component matching.
>> Audible Continuity: Audible beep indicating a complete circuit
connnection
>> RS-232 Output: Transfer data directly to a PC while performing
tests
>> Process Output: Supply 0 ~ 24mADC for testing current loops and
current loop devices
>> Waveform Display: The ability to see the actual waveform under
test. This feature is useful for determining the quality of the input
signal.
>> Duty Cycle: The total “on” time of the device under test. This
feature is useful in preventing component overheating
>> Pulse Width: Measurement of the duration of a pulse. This feature
is useful when testing pulse width modulation drive motors.
>> Logic Test: Measurement transitions of logic circuits. This feature is
useful when testing CMOS and TTL logic circuits.
>> Two Hold System: Meters with this feature can hold two readings
on the display at the same time
>> Digits: Total number of digits that can be displayed. For example, a
3½ digit meter can display a maximum of 1,999. A 3¾ digit meter can
display a maximum of 3,999. This means the 3¾ digit meter has beter
resolution capability.
>> Counts: Total number of display steps a meter has. This is
determined by adding one to the maximum display value. For example,
a 3½ digit meter can display a maximum of 1,999 and therefore has
2,000 count capability. Both digits and counts must be taken into
account when determining resolution. In general, the more counts a
meter has the higher the resolution will be.
T
T
erminology
erminology
CAT I
CAT II
CAT III
CAT IV
oven
oven
CATEGORY RATINGS
>> Category I: Usually electronic equipment or
equipment where measures have been taken to limit
transient over voltages.
>> Category II: Single phase loads like appliance
personal computers, television sets, and other
household loads. Outlets located more than 30 feet from
a CAT III source or more than 60 feet from a CAT IV
source.
>> Category III: Distribution level fixed installations like
distribution panel devices, short branch and feeder
circuits, three phase loads, and single phase
commercial lighting.
>> Category IV: Equipment and lines located on the
power line side of a service panel or where a low voltage
connection is made to utility power
underground ser
underground ser
vice
vice
commercial /
industrial
residential
batter
batter
y operated
y operated
radio
radio
telephone
telephone
refrigerator
refrigerator
furnace
furnace
power meter
power meter
distribution panel
distribution panel
light
light
distribution panel
distribution panel
power meter
power meter
copier
copier
telephone
telephone
cut off saw
cut off saw
grinder
grinder
three-phase
three-phase
motor/
motor/
conveyor
conveyor
100 120 122 126 133 135 153 163 183 190 192 194 196 440
Range Selection
Manual
Auto*/Manual •••••••
Display Specifications
2,000 Count ••
3,260 Count
4,000 Count ••
4,000 Count w/
Triple Display
4,000 Count w/
Waveform Display
50,000 Count
••••
Triple display
Analog Bar Graph ••••••
Backlight •••••
Basis Features
AC Volts •••••••••••••
DC Volts •••••••••••••
AC Amps ••••••••••
DC Amps ••••••••••
Resistance •••••••••••••
Diode Test ••••••••••
Audible Continuity ••••••••••••
Additional Features
True RMS ••••
Frequency ••••
Capacitance ••••
Inductance
Data Hold ••••••••••••
Two Hold System •••••
Min/Max Record •••••
Relative Mode •••••
Compare Mode •••••
RS-232 Output •••••
Oscilloscope Functions
Duty Cycle
Pulse Width
Logic Test
Process Output (0~24mA)
Sleep Mode/Auto Off •••••••
Range & Resolution
Basic DC Accuracy 0.5% 0.5% 0.5% 0.3% 0.5% 0.5% 0.3% 0.5% 0.3% 0.05% 0.05% 0.05% 0.05% 0.05%
DC Voltage (maximum) 600V 600V 600V 600V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V 1,000V
Input Impedance 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M
Resolution (maximum) 1mV 1mV 1mV 0.1mV 0.1mV 0.1mV 0.1mV 0.1mV 0.1mV 0.001mV 0.001mV 0.001mV 0.001mV 0.1mV
AC Voltage (maximum) 600V 600V 600V 600V 750V 750V 750V 750V 750V 750V 750V 750V 750V 1,000V
Input Impedance 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M 10M 1.11M
Resolution (maximum) 1mV 100mV 1mV 1mV 0.1mV 0.1mV 1mV 1mV 1mV 100µV 100µV 100µV 100µV 1mV
DC Amps (maximum) - - - 400mA 10A 10A 10A 10A 10A 10A 10A 10A 10A 10A
Resolution (maximum) - - - 0.1mA 0.1µA 0.01µA 0.1µA 0.1µA 0.1µA 0.01µA 0.01µA 0.01µA 0.01µA 0.1µA
AC Amps (maximum) - - - 400mA 10A 10A 10A 10A 10A 10A 10A 10A 10A 10A
Resolution (maximum) - - - 0.1mA 0.1µA 0.01µA 0.1µA 0.1µa 0.1µA 0.01µA 0.01µA 0.01µA 0.01µA 0.1µa
Resistance (maximum) 40M 2K 2K 40M 20M 40M 40M 32.6M 40M 50M 50M 50M 50M 40M
Resolution (maximum) 0.1 1 1 0.1 0.1 0.1 0.1 0.1 0.1 0.01 0.01 0.01 0.01 0.1
Frequency (maximum) --------200KHz 500KHz 500KHz 500KHz - 2MHz
Resolution (maximum) --------0.01Hz 0.001Hz 0.001Hz 0.001Hz - 0.01Hz
Capacitance (maximum) -----20,000µF - - 10,000µF 20,000µF 100µF 20,000µF - 400µF
Resolution (maximum)
-----0.1µF - - 0.01µF 0.001µF 0.1nF 0.001µF - 100pF
Inductance (maximum) ----------500mH - - -
Resolution (maximum) ----------0.01mH - - -
Agency Approval
CE IEC 1010 CAT III CAT III CAT III CAT III CAT II CAT II CAT II CAT II CAT II CAT II CAT II CAT III CAT II CAT II
600V 600V 600V 600V 1,000V / 1,000V / 1,000V / 1,000V / 1,000V / 1,000V / 1,000V / 1,000V / 1,000V / 1,000V /
CAT III CAT III CAT III CAT III CAT III CAT III CAT III CAT IV CAT III CAT III
600V 600V 600V 600V 600V 600V 600V 600V 600V 600V
CULus 3111 •••• ••• •••
*the range selection for the 100 DMM is auto only
TPI DIGITAL MULTIMETER SPECIFICATIONS