Absolute maximum ratings and operating conditions UA741
4/11 DocID5304 Rev 3
2 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
V
CC
Supply voltage ±22
VV
id
Differential input voltage ±30
V
i
Input voltage ±15
Output short-circuit duration Infinite
R
thja
Thermal resistance junction to ambient
DIP8
SO8
85
125
°C/W
R
thjc
Thermal resistance junction to case
DIP8
SO8
41
40
ESD
HBM: human body model
(1)
DIP package
SO package
1. Human body model: a 100 pF capacitor is charged to the specified voltage, then discharged through a
1.5kΩ resistor between two pins of the device. This is done for all couples of connected pin combinations
while the other pins are floating.
500
400
V
MM: machine model
(2)
2. Machine model: a 200 pF capacitor is charged to the specified voltage, then discharged directly between
two pins of the device with no external series resistor (internal resistor < 5 Ω). This is done for all couples of
connected pin combinations while the other pins are floating.
100
CDM: charged device model
(3)
3. Charged device model: all pins and the package are charged together to the specified voltage and then
discharged directly to the ground through only one pin. This is done for all pins.
1.5 kV
T
stg
Storage temperature range -65 to +150 °C
Table 2. Operating conditions
Symbol Parameter UA741I UA741C Unit
V
CC
Supply voltage 5 to 40
V
V
icm
Common mode input voltage range ±12
T
oper
Operating free air temperature range -40 to +105 0 to +70 °C