For more Information
please call
1-800-Belden1
General Description:
26 AWG stranded (7x34) tinned copper conductors, PVC insulation, aluminum/polyester foil shield, tinned
copper braid shield, 85% coverage, oil-resistant overall PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (mm)
2 26 7x34 TC - Tinned Copper 0.483
Total Number of Conductors: 4
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm) Dia. (mm)
PVC - Polyvinyl Chloride 0.254 0.991
Outer Shield
Outer Shield Material:
Type Outer Shield Material Coverage (%)
Foil Shield Alum/Mylar 100.000
Braid Tinned Copper 85.000
Outer Shield Drain Wire AWG:
Component AWG Stranding Drain Wire Conductor Material
Drain Wire 26 7x34 TC - Tinned Copper
Outer Shield Separator Material: Tissue Tape, 25% Overlap, Min.
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 1.016
Overall Cable
Overall Nominal Diameter: 6.198 mm
Pair
Pair Color Code Chart:
Number Color
1 BLACK-RED
2 BLACK-WHITE
Mechanical Characteristics (Overall)
Bulk Cable Weight: 55.063 Kg/Km
Max. Recommended Pulling Tension: 68.947 N
Min. Bend Radius/Minor Axis: 60.960 mm
Min. Bend/Installation: 60.960 mm
Min. Bend Radius (Continuous Flexing): 93.980 mm
Flex Cycle Rating: 6 Million Flexes
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CM
AWM Specification: UL Style 20006
CSA Specification: 600 V AWM I/II A/B
EU Directive 2011/65/EU (ROHS II): Yes
Other Specification: AWM/STYLE 10002, AWM/STYLE 2661, CM, AWM I/II A/B, C(UL) TYPE CMG, FT4, EU Low Voltage
Directive 2014/35/EC, EU Directive 2011/65/EU(RoHS2)
Flame Test
CSA Flame Test: FT4