Data Sheet PN10243EJ02V0DS
12
PS2705-1
SPECIFICATION OF VDE MARKS LICENSE DOCUMENT (VDE0884)
Parameter Symbol Speck Unit
Application classification (DIN VDE 0109)
for rated line voltages ≤ 300 Vr.m.s. IV
for rated line voltages ≤ 600 Vr.m.s. III
Climatic test class (DIN IEC 68 Teil 1/09.80) 55/100/21
Dielectric strength
Maximum operating isolation voltage UIORM 710 Vpeak
Test voltage (partial discharge test, procedure a for type test and random test) Upr 850 Vpeak
Upr = 1.2 × UIORM, Pd < 5 pC
Test voltage (partial discharge test, procedure b for all devices test)
U
pr = 1.6 × UIORM, Pd < 5 pC
U
pr 1 140 Vpeak
Highest permissible overvoltage UTR 6 000 Vpeak
Degree of pollution (DIN VDE 0109) 2
Clearance distance > 5 mm
Creepage distance > 5 mm
Comparative tracking index (DIN IEC 112/VDE 0303 part 1) CTI 175
Material group (DIN VDE 0109) III a
Storage temperature range Tstg –55 to +150 °C
Operating temperature range TA –55 to +100 °C
Isolation resistance, minimum value
VIO = 500 V dc at TA = 25 °C Ris MIN. 10
12
Ω
VIO = 500 V dc at TA MAX. at least 100 °C Ris MIN. 10
11
Ω
Safety maximum ratings
(maximum permissible in case of fault, see thermal derating curve)
Package temperature Tsi 150 °C
Current (input current IF, Psi = 0) Isi 200 mA
Power (output or total power dissipation) Psi 300 mW
Isolation resistance
VIO = 500 V dc at TA = 175 °C (Tsi) Ris MIN. 10
9
Ω