MAX1062
14-Bit, +5V, 200ksps ADC with 10µA Shutdown
4 _______________________________________________________________________________________
Note 1: AV
DD
= DV
DD
= +5V.
Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the full-scale range has
been calibrated.
Note 3: Offset and reference errors nulled.
Note 4: Conversion time is defined as the number of clock cycles multiplied by the clock period; clock has 50% duty cycle.
Note 5: Defined as the change in positive full scale caused by a ±5% variation in the nominal supply voltage.
MAX1062 TIMING CHARACTERISTICS (Figures 1, 2, 3, and 6)
(AV
DD
= DV
DD
= +4.75V to +5.25V, f
SCLK
= 4.8MHz (50% duty cycle), 24 clocks/conversion (200ksps), V
REF
= +4.096V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Acquisition Time t
ACQ
1.1 µs
SCLK to DOUT Valid t
DO
C
DOUT
= 50pF 50 ns
CS Fall to DOUT Enable t
DV
C
DOUT
= 50pF 80 ns
CS Rise to DOUT Disable t
TR
C
DOUT
= 50pF 80 ns
CS Pulse Width t
CSW
50 ns
CS Fall to SCLK Rise Setup t
CSS
100 ns
CS Rise to SCLK Rise Hold t
CSH
0ns
SCLK High Pulse Width t
CH
65 ns
SCLK Low Pulse Width t
CL
65 ns
SCLK Period t
CP
208 ns
(AV
DD
= +4.75V to +5.25V, DV
DD
= +2.7V to +5.25V, f
SCLK
= 4.8MHz (50% duty cycle), 24 clocks/conversion (200ksps), V
REF
=
+4.096V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Acquisition Time t
ACQ
1.1 µs
SCLK to DOUT Valid t
DO
C
DOUT
= 50pF 100 ns
CS Fall to DOUT Enable t
DV
C
DOUT
= 50pF 100 ns
CS Rise to DOUT Disable t
TR
C
DOUT
= 50pF 80 ns
CS Pulse Width t
CSW
50 ns
CS Fall to SCLK Rise Setup t
CSS
100 ns
CS Rise to SCLK Rise Hold t
CSH
0ns
SCLK High Pulse Width t
CH
65 ns
SCLK Low Pulse Width t
CL
65 ns
SCLK Period t
CP
208 ns
ELECTRICAL CHARACTERISTICS (continued)
(AV
DD
= DV
DD
= +4.75V to +5.25V, f
SCLK
= 4.8MHz (50% duty cycle), 24 clocks/conversion (200ksps), V
REF
= +4.096V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Shutdown Supply Current
I
AVDD
+
I
DVDD
CS = DV
DD
, SCLK = idle 0.1 10 µA
Power-Supply Rejection Ratio
(Note 5)
PSRR
AV
DD
= DV
DD
= +4.75V to +5.25V, full-scale
input