GQ (AGQ)
–3–
ASCTB375E 201607-T
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 2 Form C
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgNi + Au plating
Rating
Nominal switching capacity (resistive) 2 A 30 V DC, 1 A 30 V DC, 0.3 A 125 V AC
Max. switching power (resistive) 60 W (DC), 30 W (DC), 37.5 V A (AC)
Max. switching voltage 110 V DC, 125 V AC
Max. switching current 2 A (AC, DC)
Min. switching capacity (Reference value)*
1
10μA 10 mV DC
Nominal operating
power
Single side stable 140mW (1.5 to 12 V DC), 230mW (24 V DC)
1 coil latching 100mW (1.5 to 12 V DC), 120mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC)
Measured portion is the same as the case of dielectric voltage
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 1,500 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial)
Between open contacts 1,500 V (10×160μs) (FCC Part 68)
Between contact and coil 2,500 V (2×10μs) (Telcordia)
Temperature rise (at 20°C 68°F)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A)
Operate time [Set time] (at 20°C 68°F) (Initial) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F) (Initial)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 750 m/s
2
(half -sine shock pulse: 6 ms; detection time: 10μs.)
Destructive Min. 1,000 m/s
2
(half -sine shock pulse: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 5.0 mm
Expected life
Mechanical Min. 5 × 10
7
(at 180 cpm)
Electrical
Min. 1 × 10
5
(1A 30V DC resistive)
Min. 1 × 10
5
(3.5A inrush (250ms)/1A 30V AC (cos
φ
=0.4)) (ON/OFF=1s/9s)
Conditions
Conditions for operation, transport and storage*
2
Ambient temperature:
(Single side stable, 1 coil latching type) –40°C to +85°C –40°F to +185°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 1.0 g .035 oz
1. Electrical life (1 × 10
5
operation is possible)
Tested sample: AGQ21TA03, 6 pcs.
Switching frequency: ON:OFF = 1s:9s
Ambient temperature: 25°C 77°F
Circuit
Condition: 30V AC
Inrush current: 3.5A (effective value),
Inrush time 250ms
steady current: 1.0A (effective value),
(Inductive load cosφ = 0.4)
Inrush current wave form VS time
COM1 NO1
24V
60Hz
G
AC30V
Detection
Circuit
Contact Weld
Min 0.5s
Miss Contact
after 0.2s
–
+
Time (ms), Interval (100ms)
Contact Current, A
6
4
2
0
-2
-4
-6
*Precaution
When using at 3.5A, connection of NO
(pin #5 and #8) and COM (pin #4 and #9)
in the circuit is required.
Pin layout and schematic (Bottom View)
1 coil latching
Load
1234
8765