ADG508A/ADG509A
Rev. D | Page 10 of 16
TYPICAL PERFORMANCE CHARACTERISTICS
The multiplexers are guaranteed functional with reduced single or dual supplies down to 4.5 V.
600
500
400
300
200
100
–15 –10 –5 0 5 10 15
700
0
–20 20
V
D
[V
S
](V)
R
ON
(Ω)
V
DD
=+5V
V
SS
= –5V
V
DD
= +10.8V
V
SS
= –10.8V
V
DD
= +15V
V
SS
= –15V
00051-009
Figure 8. R
ON
as a Function of V
D
(V
S
): Dual-Supply Voltage, T
A
= 25°C
10
1
0.1
25
35
45 55 65 85 95 105 115
100
75 125
TEMPERATURE (°C)
LEAKAGE CURRENT (nA)
V
DD
= +16.5V
V
SS
= –16.5V
I
D
(ON)
I
D
(OFF)
I
S
(OFF)
00051-010
Figure 9. Leakage Current as a Function of Temperature
(Note: Leakage Currents Reduce as the Supply Voltages Reduce)
700
600
500
400
300
200
67891011121314
800
100
515
SUPPLY VOLTAGE (V)
t
TRANSITION
(ns)
SINGLE
SUPPLY
DUAL
SUPPLY
00051-011
Figure 10. t
TRANSITION
vs. Supply Voltage: Dual and Single Supplies, T
A
= 25°C
(Note: For V
DD
and lV
SS
l < 10 V; V1 = V
DD
/V
SS
, V2 = V
SS
/V
DD
. (see Figure 19))
600
500
400
300
200
100
–15 –10 –5 0 5 10 15
700
0
–20 20
V
D
[V
S
](V)
R
ON
(Ω)
V
DD
=10.8V
V
SS
=0V
V
DD
=15V
V
SS
=0V
00051-012
Figure 11. R
ON
as a Function of V
D
(V
S
) Single-Supply Voltage, T
A
= 25°C
1.8
1.7
1.6
1.9
1.5
678910111213145
SUPPLY VOLTAGE (V)
TRIGGER LEVEL (V)
00051-013
15
Figure 12. Trigger Levels vs. Power Supply Voltage, Dual or Single Supply,
T
A
= 25°C
0.8
0.6
0.4
0.2
678910111213141516
1.0
0
5
SUPPLY VOLTAGE (V)
I
DD
(mA)
00051-014
17
Figure 13. I
DD
vs. Supply Voltage: Dual or Single Supply, T
A