Electrical Speci cations (DC)
Over recommended operating T
A
= - 40°C to 85°C, I
F
= 5mA to 10mA, unless otherwise speci ed.
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Output Withstand Voltage | V
O(OFF)
| 600 650 V
V
F
=0.8V, I
O
=250μA, T
A
=25°C
550 V
V
F
=0.8V, I
O
=250μA
Output
On-Resistance
Connection A R
(ON)
10 16
Ω
I
F
=5mA, I
O
=0.2A,
Pulse ≤30ms, T
A
=25°C
3
10
-
6
Connection B R
(ON)
2.5 4
Ω
I
F
=5mA, I
O
=0.4A,
Pulse ≤30ms, T
A
=25°C
11 6
Output Leakage Current I
O(OFF)
0.001 0.1
μA
V
F
=0.8V, V
O
=600V, T
A
=25°C 5 -
1
μA
V
F
=0.8V, V
O
=550V 4 -
Output O -Capacitance C
(OFF)
500 pF V
F
=0.8V, V
O
=0V, f=1MHz 6 -
Output O set Voltage | V
(OS)
|1
μV
I
F
=5mA, I
O
=0mA
Input Reverse Breakdown Voltage V
R
5V
I
R
=10μA
Input Forward Voltage V
F
1.1 1.3 1.7 V I
F
=5mA 7,8 -
Switching Speci cations (AC)
Over recommended operating T
A
= - 40°C to 85°C, I
F
= 5mA to 10mA, unless otherwise speci ed.
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Turn On Time T
ON
0.7 2.5 ms I
F
=5mA, I
O
=0.2A, T
A
=25°C 12,16
5.0 ms I
F
=5mA, I
O
=0.2A 13,16
0.4 1.5 ms I
F
=10mA, I
O
=0.2A, T
A
=25°C 12,16
3.0 ms I
F
=10mA, I
O
=0.2A 13,16
Turn O Time T
OFF
0.07 0.5 ms I
F
=5mA, I
O
=0.2A, T
A
=25°C 14,16
1msI
F
=5mA, I
O
=0.2A 15,16
0.06 0.2 ms I
F
=10mA, I
O
=0.2A, T
A
=25°C 14,16
0.5 ms I
F
=10mA, I
O
=0.2A 15,16
Output Transient Rejection dV
O
/dt 1 7
kV/μs
ΔV
O
=600V, R
M
≥ 1MΩ,
C
M
=1000pF, T
A
=25°C
17 5
Input-Output Transient
Rejection
dV
I-O
/dt 1 20
kV/μs
V
DD
=5V, ΔV
I-O
=1000V,
R
L
=1kΩ, C
L
=25pF, T
A
=25°C
18 5
Notes:
1. For derating, refer to Figure 1 and 2.
2. The voltage across the output terminal of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should be
added in some applications to protect against over-voltage transients.
3. Device is considered as a two terminal device: pins 1, 2, and 3 shorted together and pins 5, 6, and 7 shorted together.
4. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety speci cation, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
5. During the pulsed R
(ON)
measurement ( I
O
duration ≤30ms), ambient (T
A
) and case temperature (T
C
) are equal.
6. For the transient rejection measurements, refer to Avago whitepaper, AV01-0610EN, “Solid State Relay Transient Immunity”.