(6/7)
20170612 / 3tf_commercial_signal_mea1210pe_en.fm
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
MEA1210PE Type
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS SPECIFICATION TABLE
○ Measurement equipment
* Equivalent measurement equipment may be used.
INSERTION LOSS VS. FREQUENCY CHARACTERISTICS
○ Measurement equipment
* Equivalent measurement equipment may be used.
Capacitance
(pF)
Cutoff frequency
(MHz)typ.
Insertion loss 20dB
frequency range
(MHz)
Rated voltage
(V)max.
Rated current
(mA)max.
Part No.
40 210 470 to 3000 6.3 100 MEA1210PE400T001
36 220 470 to 3000 6.3 100 MEA1210PE360T001
22 250 470 to 3000 6.3 100 MEA1210PE220T001
Measurement item Product No. Manufacturer
Capacitance 4294A Keysight Technologies
Frequency characteristics N5230C Keysight Technologies
Product No. Manufacturer
N5230C Keysight Technologies
10
0
20
30
40
50
70
60
10 100 100001000
400
360
220
Insertion loss
(
dB
)
Frequency
(
MHz
)
The products will be or have been
stopped production