Type EDLR electric double layer supercapacitors oer high capacitance
values in a thru hole stacked coin type package. Primarily designed
for integrated circuit voltage backup, the capacitors can also be used
to deliver the initial power from batteries.
Highlights
- Long life
- High discharge current
- 85 ºC Operating temperature
Specications
Operating Temperature Range –25 ºC to +85 ºC
Rated Voltage Range 3.6 Vdc to 5.5 Vdc
Capacitance Range 0.1 F to 1.0 F
Type
Capacitance (F)
Voltage (Vdc)
Capacitance Tolerance (%)
Max. Initial Internal Resistance (ohms at 1kHz)
Life, Moisture and Temperature Characteristics After the following procedures have been performed, measure the capaci-
tance and internal resistance at +20 ºC.
Life Test: Apply the max. operating voltage for 2000 h at +85 ºC
Capacitance Change
Internal Resistance
±30% of the initial measured value at +20 ºC
≤ 2 times the initial specied value
Shelf Life: Subject the capacitor to 2000 hours without voltage at +85 ºC.
Capacitance Change
Internal Resistance
±30% of the initial measured value at +20 ºC
≤ 2 times the initial specied value
Moisture Resistance: Subject the capacitor to 500 hours at +55 ºC at 90 to 95% RH without
voltage.
Capacitance Change
Internal Resistance
±10% of the initial measured value at +20 ºC
meets the initial specied value
Soldering Heat Resistance: Immerse the capacitor leads to within 2 mm of the capacitor body in
solder that is at a temperature of 260 ºC for 10 seconds.
Capacitance Change
Internal Resistance
±10% of the initial measured value at +20 ºC
meets the initial specied value
Temperature Cycling Stabilize the capacitor at each of the following temperatures for 1 hour in
sequence, and then measure the capacitance and internal resistance at
that temperature.
1. +20 ºC
2. -25 ºC
3. +20 ºC
4. +85 ºC
5. +20 ºC
Capacitance Change (at -25 ºC)
Internal resistance (at -25 ºC)
Capacitance Change (at +85 ºC)
Internal resistance (at +85 ºC)
Capacitance Change (Step 5 at +20 ºC)
Internal resistance (Step 5 at +20 ºC)
±30% of the initial measured value at +20 ºC
≤ 5 times the initial measured value at +20 ºC
±30% of the initial measured value at +20 ºC
≤ 4 times the initial measured value at +20 ºC
±10% of the initial measured value at +20 ºC
meets the initial specied value
RoHS Compliant without Exemptions
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type EDLR, Long Life Electric Double Layer Ultracapacitor
RF RD RG
0.10 0.68 0.22 1.0
5.5 3.6
-20 to +80
75 20 50 20