SpecNo.JELF243A-9139-01 P.3/11
MURATA MFG.CO.,LTD
Reference Only
4. Appearance and Dimensions
■Unit Mass (Typical value)
0.003g
(in mm)
5.Electrical Performance
No. Item Specification Test Method
5.1
Inductance
Inductance shall meet item 3. Measuring Equipment:
KEYSIGHT E4991A or equivalent
Measuring Frequency:
<Inductance> 250MHz/ 1.6nH~43nH
200MHz/ 47nH~68nH
150MHz/ 72nH~150nH
100MHz/ 180nH~390nH
<Q> 250MHz/ 1.6nH~43nH
200MHz/ 47nH~68nH
150MHz/ 72nH~150nH
100MHz/ 180nH~390nH
Measuring Condition:
Test signal level / about 0dBm
Electrode spaces / 1.0 mm
Electrical length/ 10.0mm
Measuring Fixture: KEYSIGHT 16197A
Position coil under test as shown in below
and contact coil with each terminal by
adding weight.
Measuring Method:See P.10
<Electrical Performance:Measuring
Method of Inductance/Q>
5.2 Q Q shall meet item 3.
5.3 DC Resistance DC Resistance shall meet item 3. Measuring Equipment:Digital multi meter
5.4 Self Resonant
Frequency
(S.R.F)
S.R.F shall meet item 3. Measuring Equipment:
KEYSIGHT N5230A or equivalent
1.6±0.2
0.3±0.1
0.8±0.2
0.4 max.
0.2±0.1
0.3±0.1
0.8±0.15
0.8±0.2
1608 size guide