G3B/G3BD
■ Accessories (Order Separately)
Connecting Sockets/Hold-Down Clips
Specifications
■ Ratings (at an Ambient Temperature of 25C)
Input
Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for Solid State Relays.
2. Constant-current input circuit.
Output
Note: The load current depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data for details.
■ Characteristics
Front-mounting Sockets Back-mounting Sockets
Socket PF083A(-E) PL08 PLE08-0 PL08-Q
Hold-down Clip PFC-A1 PLC PLC-10 PLC
Model Rated voltage Operating voltage Input current Voltage levels
Must operate voltage Must release voltage
G3B-205S-VD 5 to 24 VDC 4 to 30 VDC 15 mA max. (See note.) 4 VDC max. 1 VDC min.
G3BD-103S-VD 1.5 k+20%/10%
Model Applicable load
Rated load voltage Load voltage range Load current (See note.) Inrush current
G3B-205S-VD 100 to 240 VAC 75 to 264 VAC 0.1 to 5 A at 40C 80 A, 60 Hz for 1 cycle
G3BD-103S-VD 5 to 110 VDC 3 to 125 VDC 0.1 to 3 A at 40C 12 A (10 ms)
Model G3B-205S-VD G3BD-103S-VD
Operate time 1/2 cycle of load power source + 1 ms max. 0.5 ms max.
Release time 1/2 cycle of load power source + 1 ms max. 2.5 ms max.
Output ON voltage drop 1.6 V (RMS) max. 1.5 V max.
Leakage current 5 mA max. (at 100 VAC); 10 mA max. (at 200 VAC) 5 mA max. (at 125 VDC)
Insulation resistance 100 M min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Shock resistance
1,000 m/s
2
Ambient temperature Operating: –30C to 80C (with no icing or condensation)
Storage: –30C to 100C (with no icing or condensation)
Ambient humidity 45% to 85%
Certified standards G3B: UL508, CSA C22.2 No. 14, EN60947-4-3
G3BD: UL508, CSA C22.2 No. 14, EN60950-1
EMC Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
Weight Approx. 70 g