Data Sheet 4 V1.1, 2007-09-25
Smart High-Side Power Switch
BTS723GW
arameter Symbol Values Unit
upply voltage (overvoltage protection see page 6)
V
bb
58 V
upply voltage for full short circuit protection
j,start
=-40 ...+150°C
V
bb
50 V
utput Voltage to V
bb
V
ON
70 V
egative voltage slope at output -d
V
OUT
/d
t
20 V/µs
oad current (Short-circuit current, see page 7)
I
L
I
L(LIM)
1
)
A
oad dump protection
2)
V
LoadDump
=
V
A
+
V
s
,
V
A
= 27 V
R
I
3)
= 8 Ω,
t
d
= 200 ms; IN= low or high,
each channel loaded with
R
L
=20 Ω,
V
Load dump
4
)
70 V
perating temperature range
torage temperature range
T
j
T
stg
-40 ...+150
-55 ...+150
°C
Power dissipation (DC)
5)
T
a
= 25°C:
(all channels active)
T
a
= 85°C:
P
tot
3.0
1.6
W
aximal switchable inductance, single pulse
V
bb
= 12V,
T
j,start
= 150°C
5)
,
I
L
= 2.5 A,
E
AS
= 110 mJ, 0 Ω one channel:
I
L
= 3.5 A,
E
AS
= 278 mJ, 0 Ω two parallel channels:
ee diagrams on page 12
Z
L
23.0
30.0
mH
Electrostatic discharge capability (ESD):
Human Body Model) acc. MIL-STD883D, method 3015.7 and ESD
ssn. std. S5.1-1993 R=1.5kΩ; C=100pF
V
ESD
1.0 kV
Input voltage (DC)
V
IN
±42 V
urrent through input pin (DC)
urrent through status pin (DC)
I
IN
I
ST
±2.0
±2.0
mA
tatus pull up voltage
V
SPU
±42 V
) Current limit is a protection function. Operation in current limitation is considered as "outside" normal
operating range. Protection functions are not designed for continuous repetitive operation.
)
Supply voltages higher than V
bb(AZ)
require an external current limit for the GND and status pins (a 150Ω
resistor for the GND connection is recommended.
)
R
I
= internal resistance of the load dump test pulse generator
)
V
Load dump
is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839
)
Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm
2
(one layer, 70µm thick) copper area for V
bb
connection. PCB is vertical without blown air. See page 15