SMP100MC Application information
Doc ID 9699 Rev 5 9/13
Figure 16. Test circuit 1 for Dynamic I
BO
and V
BO
parameters
Figure 17. Test circuit 2 for I
BO
and V
BO
parameters
100 V / µs, di/dt < 10 A / µs, Ipp = 100 A
1 kV / µs, di/dt < 10 A / µs, Ipp = 10 A
U
U
10 µF
2 Ω
45 Ω
66 Ω
470 Ω
83 Ω
0.36 nF
46 µH
60 µF
26 µH
12 Ω
250 Ω
46 µH
47 Ω
KeyTek 'System 2' generator with PN246I module
KeyTek 'System 2' generator with PN246I module
220V 50Hz
1/4
R1 = 140W
R2 = 240W
K
ton = 20ms
IBO
measurement
VBO
measurement
Vout
DUT
TEST PROCEDURE
Pulse test duration (tp = 20ms):
V selection:
●
●
●
●
for Bidirectional devices = Switch K is closed
for Unidirectional devices = Switch K is open
Device with V < 200 V V = 250 V , R1 = 140
OUT
BO OUT RMS
➔ W
Device with V 200 V V = 480 V , R2 = 240
BO OUT RMS
³W➔