Page 10 of 20
©2011 Knowles Electronics
Release Revision: C
2403 260 00091
3. Electrical and Acoustical Specifications
3.1. Frequency response
Typical frequency response measured on baffle according to chapter 3.5 and 3.6
(distance d = 1cm calculated to 10cm, p= 700mW, 1ccm)
Tolerance window
Frequency Response
THD
f
[Hz]
lower limit
[dBSPL]
upper limit
[dBSPL]
f
[Hz]
upper limit
[%]
300
70
80
200
40
770
-
100
400
40
900
94
-
700
14
1000
94
100
1000
8
2000
90
-
2000
3
2300
-
95
10000
3
6000
-
95
8000
90
-
9000
-
101
14000
-
103
16000
92
-
18000
85
-
20000
85
103
0
10
20
30
40
50
60
70
70
75
80
85
90
95
100
105
100 1000 10000
THD [%]
SPL [dB rel 20uPa]
f [Hz]
SPL [dB] THD Limit
Page 11 of 20
©2011 Knowles Electronics
Release Revision: C
2403 260 00091
3.2. Electro-Acoustic Parameters
Loudspeaker mounted in adapter acc. to 3.6 in setup acc. to 3.5.
1. Rated impedance Z: 6
2. Voice coil DC resistance R: 5,4±10%
3. Resonance frequency (measured @1ccm, 700mW) f
0
: 850H7,5%
3.1 Typical resonance frequency (measured @open back, 0,5V) f
0
: 500Hz
4. Maximum usable excursion xmax p-p: 0.74mm p-p
5. Measured characteristic sensitivity 74±2dB
(measured at 1W in 1cm, calculated to 1m
average from 2kHz to 6kHz, thermal compression included)
5.1. Measured characteristic sensitivity (at 1V in 10cm) 87,2±2dB
average from 2kHz to 6kHz
6. THD according chapter 3.1.
7. Rub & buzz no audible R&B at max sine power
All acoustic measurements at 23±2°C
3.3. Power Handling
Speaker mounted in 1ccm test device (open front)
1. Max sine power f1kHz 1000mW
f<1kHz 700mW
(at 1ccm if no extra damping is provided)
2. Max short term power (70°, 1sec. ON / 60sec. OFF) 1200mW (RMS)
(pink noise, 2
nd
order high pass filtered, -3dB at 1.2kHz, crest factor 2)
3. Max continuous power (70°, 500h) 1000mW (RMS)
(white noise, 2
nd
order high pass filtered, -3dB at 100Hz, 2
nd
order low pass filtered, -3dB at 8kHz, crest factor 2)
Page 12 of 20
©2011 Knowles Electronics
Release Revision: C
2403 260 00091
3.4. Measured Parameters
3.4.1. Sensitivity
SPL is expressed in dB rel 20µPa, computed according to IEC 268-5.
Measurement set up and parameters according chapter 3.5.
This test is performed for 100% of products in the production line.
3.4.2. Frequency response
Frequency response is measured according test set up in chapter 3.5 data sheet and checked against
the tolerance window defined in chapter 3.1. This Test is performed for 100% of products in the
production line.
3.4.3. Total harmonic distortion (THD)
Is measured according IEC 268-5 (2nd to 5th harmonics) and test set up in chapter 3.5. This test is
performed for 100% of products in the production line.
3.4.4. Rub& Buzz
Rub & Buzz will be measured in the Inline-measuring device with a sinusoidal sweep. Rub and Buzz is
defined as the maximum peak sound pressure in transmission range of the 5kHz high pass filter.
This test is performed for 100% of products in the production line.
3.5. Measurement setup
Measurement signal: Logarithmic sine sweep, 1.5s, 22kHz-180Hz
d
analyzer
frequency
response
THD
rub & buzz
Measurement adapter
Power amplifier
IEC
BAFFLE
Freefield microphone
1/4“
R
q, including wiring
< 0,3
1cm³

2403 260 00091

Mfr. #:
Manufacturer:
Knowles
Description:
Speakers & Transducers Speaker - Cobra
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS