Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40°C (25°C) @ 250 VAC/50 Hz L Cx Cy R connections
(@ 120 VAC/60 Hz)
[A] [mA] [mH] [μF] [nF] [kΩ]
[g]
FN 2060-1-.. 1 (1.2) 0.66 (0.38) 12 0.22 4.7 1000 -06 -07 120
FN 2060-3-.. 3 (3.5) 0.66 (0.38) 2.5 0.22 4.7 1000 -06 -07 120
FN 2060-6-.. 6 (6.9) 0.66 (0.38) 0.97 0.22 4.7 1000 -06 -07 120
FN 2060-10-.. 10 (11.5) 0.66 (0.38) 0.8 0.47 4.7 470 -06 -07 190
FN 2060-12-.. 12 (13.8) 0.66 (0.38) 0.58 0.47 4.7 470 -06 -07 190
FN 2060-16-.. 16 (18.4) 0.66 (0.38) 0.65 0.33 4.7 1000 -06 -07 -08 260
FN 2060-20-.. 20 (23) 0.66 (0.38) 0.6 1 4.7 220 -06 -08 480
FN 2060-30-08 30 (34.5) 0.79 (0.45) 0.6 1 10 220 -08 950
FN 2060A-1-.. 1 (1.2) 0.07 (0.04) 12 0.22 0.47 1000 -06 -07 120
FN 2060A-3-.. 3 (3.5) 0.07 (0.04) 2.5 0.22 0.47 1000 -06 -07 120
FN 2060A-6-.. 6 (6.9) 0.07 (0.04) 0.97 0.22 0.47 1000 -06 -07 120
FN 2060A-10-.. 10 (11.5) 0.07 (0.04) 0.8 0.47 0.47 470 -06 -07 190
FN 2060A-12-.. 12 (13.8) 0.07 (0.04) 0.58 0.47 0.47 470 -06 -07 190
FN 2060A-16-.. 16 (18.4) 0.07 (0.04) 0.65 0.33 0.47 1000 -06 -07 -08 260
FN 2060A-20-.. 20 (23) 0.07 (0.04) 0.6 1 0.47 220 -06 -08 480
FN 2060A-30-08 30 (34.5) 0.07 (0.04) 0.6 1 0.47 220 -08 950
FN 2060B-1-.. 1 (1.2) 0.00 12 0.22 1000 -06 -07 120
FN 2060B-3-.. 3 (3.5) 0.00 2.5 0.22 1000 -06 -07 120
FN 2060B-6-.. 6 (6.9) 0.00 0.97 0.22 1000 -06 -07 120
FN 2060B-10-.. 10 (11.5) 0.00 0.8 0.47 470 -06 -07 190
FN 2060B-12-.. 12 (13.8) 0.00 0.58 0.47 470 -06 -07 190
FN 2060B-16-.. 16 (18.4) 0.00 0.65 0.33 1000 -06 -07 -08 260
FN 2060B-20-.. 20 (23) 0.00 0.6 1 220 -06 -08 480
FN 2060B-30-08 30 (34.5) 0.00 0.6 1 220 -08 950
*
* To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2060-30-08, FN 2060B-10-06).
** Maximum leakage under usual AC operating conditions (acc. IEC 60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Leakage current for DC application is 0 mA;