GKE Series
2 www.honeywell.com/sensing
SPECIFICATIONS
Designation and
Utilization Category
Rated Operational Current Ie (A) at Rated Operational Voltage Ue (V)
24 V 120 V 240 V 380 V 480 V 500 V 600 V
AC15 A500
—
6 A 3 A 1,9 A 1,5 A 1,4 A —
AC15 A600
—
6 A 3 A 1,9 A 1,5 A 1,4 A 1,2 A
DC13 Q300
2,8 A 0,55 A 0,27 A
— — — —
Rated thermal current (Ith)
10 A
Sealing
IP66; NEMA 1, 12, 13
Rated impulse withstand (Uimp)
2500 V
Pollution degree
3
Rated insulation voltage (Ui)
500 V, 600 V
Operating temperature
range
-25 °C to 85 °C [-13 °F to 185 °F]
Short-circuit protective device
(type/max. rating)
Class J fuse (10 A/600 V)
Mechanical life
1,000,000 operations
Conditional short-circuit current
1000 A
—
—
Complies with:
Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC.
Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function.
IEC/EN60947-5-1.
MOUNTING DIMENSIONS (For reference only mm [in])
CONDUIT THREAD
30,5
[1.20]
59,3
[2.33]
92,2
[3.63]
30,5
[1.20]
55,0
[2.17]
23,3
[0.92]
24,2
[0.95]
37,2
[1.46]
3,0
[0.12]
30,5
[1.20]
22,0
[0.87]
20,0
[0.79]
7,2 [0.28] FOR 1/2-14 NPT
CONDUIT THREAD
3,5 [1.38] FOR 20 mm X 1,5
CONDUIT THREAD
29,4
[1.16]
Head Code L Head Code M Head Code N Head Code P
13,50
[0.53]
12,50
[0.49]
11,50
[0.45]
12,50