PP023 Passive Probe
2
Specifications
Model Attn.
Input
Imped.
B/W
Rise
Time
Length
Compensation
Range
R (MΩ) C (pF) (MHz) (ps) (m) (pF)
PP023
10x
10
10
500
700
1.3
10 - 20
Attenuation Ratio ..................... 10:1 ± 1%
Max. Input Voltage................... Measurement Category I
1
: 500 Vrms
1500 V transient overvoltage
(see voltage derating curve on p. 3)
Measurement Category II
2
: 400 Vrms
Pollution Degree ...................... Pollution Degree 2
3
Operating Temperature .......... C to +50° C
Humidity .................................... 5% to 95% RH (10° C to 30° C)
5% to 75% RH (30° C to 40° C)
5% to 50% RH (above 40° C)
RH not controlled below 10° C
Operating Altitude .................... 3000 meters maximum
To reduce risk of fire or electric shock, do not exceed the
voltage or category ratings of the probe.
Definitions (per EN 61010-031)
1) Measurement Category I (CAT I) refers to measurements performed on circuits not directly
connected to mains.
2) Measurement Category II (CAT II) refers to measurements performed on circuits directly
connected to the low-voltage installation.
3) Pollution Degree 2 refers to an operating environment where normally only dry, non-conductive
pollution occurs. Temporary conductivity caused by condensation must be expected.
Operator’s Manual
3
PP023 Input Impedance Profile
Voltage vs. Frequency Derating Curve
PP023 Passive Probe
4
EC Declaration of Conformity
The probe is marked with this symbol to show compliance was
demonstrated to the specifications listed in the Official Journal of
the European Communities: Low Voltage Directive 2006/95/EC:
EN 61010-031/A1:2008 Safety requirements for electrical equipment for
measurement, control and laboratory use Part 031: Safety requirements
for handheld probe assemblies for electrical measurement and test.
EU RoHS Compliance
The probe and its accessories conform to the 2011/65/EU RoHS2 Directive,
as they have been classified as Industrial Monitoring and Control
Equipment (per Article 3, Paragraph 24) and are exempt from RoHS
compliance until 22 July 2017 (per Article 4, Paragraph 3).
General Safety Information
Observe generally accepted safety procedures in addition to those
listed here to avoid personal injury or damage to equipment.
The
overall safety of any system incorporating this accessory is the
responsibility of the assembler of the system.
Connect only to grounded instruments. Use only with compatible Teledyne
LeCroy oscilloscopes that have their BNC input connected to an earth
ground. Do not connect the probe reference lead to any point which is at a
potential other than earth ground.
Connect and disconnect properly. Connect probe to the oscilloscope before
connecting it to the test circuit. Disconnect the probe input and reference
lead from the test circuit before disconnecting from the oscilloscope. Do
not connect or disconnect probes while they are connected to a voltage
source.

PP023-1

Mfr. #:
Manufacturer:
Description:
LeCroy, Probe, Passive, 500 MHz, 2.5mm, 10:1, 10 MOhm
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union